Cisco Cisco Web Security Appliance S160

Pagina di 64
 
  Known Issues
42
Release Notes for Cisco IronPort AsyncOS 7.1 for Web
OL-23206-01
Known Issues
 lists the known issues in this release of AsyncOS for Web.
Table 5
Known Issues for AsyncOS 7.0 for Web
Defect ID
Description
72796
An application fault occurs when rebooting the appliance very soon after 
upgrading from a previous version in some cases
An application fault occurs with the internal logging process when you upgrade 
AsyncOS from a previous version and reboot the appliance and then reboot the 
appliance again within a few minutes after the upgrade and reboot complete.
Workaround: Contact Cisco IronPort Customer Support to delete an internal file and 
then reboot the appliance again. 
72834
An application fault occurs in the internal reporting process when you change the 
system time or time zone on the appliance in some cases
An application fault occurs in the internal reporting process when you change the 
system time or time zone on the appliance after it has processed traffic. Additionally, 
for some appliances, data is not aggregated properly (for example, hourly data is not 
aggregated into the daily data). This may result in performance degradation, and 
eventually, into data retention issues.
Workaround: Contact Cisco IronPort Customer Support to disable and then enable the 
reporting process. 
72835
Export link is missing on the Reports By User Location report page for the 
“Suspect Transactions Detected” charts
The Export link is missing on the Reports By User Location report page for the 
“Suspect Transactions Detected” charts for both Remote and Local users. 
Workaround: Export data from the Suspect Transactions Summary charts instead.
71942
Logging data is recorded on Web Security appliance after enabling Centralized 
Reporting
When you enable Centralized Reporting on the Web Security appliance, AsyncOS for 
Web records information in the Web Security appliance logging database as well as 
collects information for centralized reporting on the Security Management appliance. 
Workaround: After enabling Centralized Reporting on the Web Security appliance, 
reboot the Web Security appliance.