Power Supply Replacement Procedure for the Cisco MeetingPlace 8106
OL-6459-01
  How To Replace the Power Supply
Step 4
Slide the power supply out of the power supply bay. See 
Figure 2
Removing the Cisco MeetingPlace 8106 Power Supply
Installing the New Power Supply
Warning
Do not touch any of the exposed leads, terminals, or components. Hazardous voltages, capable of 
causing death, may be present in this product.
Step 1
Remove the new power supply from the antistatic bag.
Step 2
Insert the bottom edges of the power supply into the rail guides in the power supply bay. If you can tilt 
the power supply more than 2 degrees after it is in the power supply bay, both edges are not in the rail 
guides.
Step 3
Slide the power supply into the power supply bay until it stops. You hear a click when it is completely in.
Step 4
Use your thumbs to press the power supply into the power supply bay so that the front panel of the power 
supply is flush with the chassis.
Caution
Do not force the power supply into the slot. This can damage the power supply and the 
Cisco MeetingPlace 8106 chassis.
Step 5
Secure the power supply in the power supply bay by pushing the black handle in towards the chassis. 
The Input OK LED illuminates after the power supply successfully connects to the chassis.
Caution
Do not force the handle closed. If the connectors are misaligned, you can bend and break the pins.
Step 6
Use a Phillips screwdriver to replace the screw in the latching mechanism. The latching mechanism is 
located on the front right of the power supply.
Step 7
Manually tighten the screw that secures the power supply to the Cisco MeetingPlace 8106 chassis. This 
screw is located on the front left of the power supply. No screwdriver is needed.
Fault
Input OK
POWER-ONE
N
E
T
1
N
E
T
2
C
O
M
1
RESET
V
I
D
E
O
P
V
C
1
2
M
O
U
S
E
K
B
D
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
HO
T SW
AP
LINK
100Mb
ACTIVITY
1
2
3
4
Fault
Input OK
POWER-ONE
122225