Cisco Cisco Unified MeetingPlace 5.3 Manuale Di Manutenzione

Pagina di 8
 
6
Hot Swap Controller Replacement Procedure for the Cisco MeetingPlace 8112
OL-6466-01
  How to Replace the Hot Swap Controller
Backing up the Database
Back up the Cisco MeetingPlace 8112 database before you replace the hot swap controller. (You can use 
the backup to restore your data if there is a problem after the installation.) We recommend that you back 
up your database immediately before replacing the hot swap controller.
Note
Use the Cisco MeetingPlace Backup Gateway to back up your database. For information on how to 
install, configure, and use the Cisco MeetingPlace Backup Gateway, see the Administrator’s Guide for 
Cisco MeetingPlace Backup Gateway Release 5.3.
Powering Down the Cisco MeetingPlace 8112
Note
As a courtesy, notify any current users that you are powering down the Cisco MeetingPlace 8112.
Step 1
Access the CLI.
Step 2
Log in as an administrator. The tech$ prompt appears.
Step 3
To stop new Cisco MeetingPlace activity, enter down. A verification prompt appears.
Step 4
At the prompt, enter y. The power down cycle begins.
Step 5
Wait about 2 minutes for the power down cycle to complete.
Step 6
At the tech$ prompt, enter halt. A verification prompt appears.
Step 7
At the prompt, enter y.
Step 8
Locate the power switch on the back of the Cisco MeetingPlace 8112 and turn it to the off position (“O”). 
Step 9
Remove the power cable from the back of the Cisco MeetingPlace 8112.
How to Replace the Hot Swap Controller
The hot swap controller consists of only a card with no corresponding transition module. Replacing the 
hot swap controller for the Cisco MeetingPlace 8112 consists of the following activities:
Removing the Old Hot Swap Controller Card
Caution
Handling the hot swap controller card can result in static damage. Use an antistatic wrist strap, 
static-dissipating work surface, and antistatic bags when handling and storing the hot swap controller 
card.