Cisco Cisco UCS M4308 Modular Chassis Scheda Tecnica

Pagina di 32
Cisco UCS M4308 Modular Chassis
30
TECHNICAL SPECIFICATIONS
For configuration-specific power specifications, use the Cisco UCS Power Calculator at this URL:
Environmental Specifications
The power specifications for the M4308 chassis are listed in 
.
Table 19  UCS M4308 Environmental Specifications
Parameter
Minimum
Temperature operating
41 to 104° F (5 to 40° C)
derate the maximum temperature by 1°C per every 305 m of 
altitude above sea level
Temperature nonoperating
–40 to 149°F (–40 to 65°C)
Humidity (RH) operating, 
non-condensing
10 to 90%
Altitude operating
0 to 3,000 m (0 to 10,000 ft.)
Altitude nonoperating
0 to 12,192 m (0 to 40,000 ft.)
Sound Power level, Measure 
A-weighted per ISO7779 LWAd (Bels) 
Operation at 73°F (23°C) 
5.8 Bel
Sound Pressure level, Measure 
A-weighted per ISO7779 LpAm (dBA) 
Operation at 73°F (23°C) 
43 dbA
Shock
5.0G, 11msec pulse width, half sine wave