Cisco Cisco UCS C210 M2 General-Purpose Rack Server Scheda Tecnica

Pagina di 86
Cisco UCS Cisco UCS C220 M3 High-Density Rack Server (Large Form Factor Hard Disk Drive Model)
24
CONFIGURING the SERVER
UCSC-RAID-MZ-220
Cisco UCSC RAID SAS 2008M-8i Mezzanine Card (RAID 0, 1, 10 plus JBOD 
supported), operating at 6 Gbs.
Supports up to eight internal SAS+SATA drives (limited to four drives for 
the C220 M3 LFF chassis). SAS and SATA drives can be mixed.
Factory-configured RAID options available: RAID 0, 1, and 10 (see the RAID 
PIDs section in this table)
No data cache backup
Table 9   Available PCIe RAID Controller Options 
Product ID (PID)
PID Description
RAID Controllers
a
 
Note that PCIe RAID controllers are installed by default in slot 1 for 1-CPU systems and slot 2 for 
2-CPU systems)
UCS-RAID9271-8I or
UCS-RAID9271CV-8I
LSI MegaRAID SAS 9271-8i or 9271CV-8i RAID controller card with data cache 
backup (RAID 0, 1, 10, 5, 6, 50, 60), operating at 6 Gbs.
Supports up to eight internal SAS+SATA drives (limited to four drives for 
the C220 M3 LFF chassis). SAS and SATA drives can be mixed.
Includes a 1 GB Transportable Flash Module (TFM) and a chassis-mounted 
(remote) supercapacitor for data cache power backup (supercapacitor not 
available on the 9271-8i)
Factory-configured RAID options available: RAID 0, 1, 5, 6, and 10, (see 
the RAID PIDs section in this table)
Table 8   Available Mezzanine Card RAID Options (continued)
Product ID (PID)
PID Description
NOTE:  For any application requiring Virtualization support (VMs), with 
write cache/scalable performance, use the 9271CV-8I RAID controller 
instead of the mezzanine RAID controllers (UCSC-RAID-11-C220 or 
UCSC-RAID-MZ-220), as the latter controllers do not support a write 
cache.