Cisco Cisco UCS B200 M4 Blade Server Scheda Tecnica

Pagina di 64
Cisco UCS B260 M4 Blade Server (with Intel® Xeon E7 v3 CPU)
SUPPLEMENTAL MATERIAL
59
In 
, one port from the VIC 1340/1240 is connected to Fabric Extender A and one is connected to 
Fabric Extender B. The Port Expander Card for the VIC 1340/1240 installed in adapter slot 2 has no role in 
this case. In addition, the VIC 1380/1280 channels one port to each Fabric Extender. The result is 20 Gb of 
bandwidth to each Fabric Extender.
Figure 20
  VIC 1340/1240, Port Expander  in adapter slot 2, and VIC 1380/1280 in adapter slot 3
In 
, two ports from the VIC 1340/1240 are connected, one to each Fabric Extender. A Cisco UCS 
Storage Accelerator adapter is installed in slot 2, but provides no network connectivity. The VIC 1380/1280 
installed in adapter slot 3 connects two ports, one to each of the Fabric Extenders. The result is 20 Gb of 
bandwidth to each Fabric Extender.
Figure 21
  VIC 1340/1240, Cisco UCS SA adapter slot 2, and VIC 1380/1280 in adapter slot 3