Cisco Cisco UCS B200 M4 Blade Server Scheda Tecnica

Pagina di 15
 
Figure 5.    DIMM Slot Numbering 
 
Each channel pair is identified by a letter: A, B, C, or D for each CPU. Each DIMM pair member is identified by 
numbers, 0, 1, 2 or 3. Additional DIMMs must be installed as shown in Table 2. 
1
 The slots inside the brackets are electrically paired with each other, and should be populated with identical matched 
DIMMs that were ordered as a pair. Do not swap a paired DIMM with a DIMM that is not identical in manufacturer part 
number. 
 
RAID Controller Notes 
The LSI-2008 is an eight port, 6Gb/s SAS/SATA RAID On-a-Chip (ROC) VLSI IC. The LSI-2008 ROC provides a 
x8 PCIe Gen2 interface, which is connected as x4 on the B230 server board. 
The LSI-2008 SAS/SATA Controller is embedded on the motherboard and supports the following features: 
 
● 
RAID 0, 1 
 
LSI-2008 Flash ROM 
The LSI-2008 requires a minimum of 8Mbyte Flash ROM configured for 8-bit I/O. The Flash ROM contains code for 
the System Optional BIOS, which is needed for booting the RAID array, and also RAID firmware for the embedded 
CPU. 
 
 
Contents:
 
 
 
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. 
Page 13 of 15