Cisco Cisco Firepower Management Center 2000 Guida Dello Sviluppatore

Pagina di 726
Version 5.3
Sourcefire 3D System eStreamer Integration Guide
104
Understanding Intrusion and Correlation Data Structures
Intrusion Event and Metadata Record Types
Chapter 3
 on page 30.) Note that the record type field, which appears after 
the message length field, has a value of 129, indicating a malware event subtype 
record.
The 
 table describes the fields in the 
malware event subtype record.
FireAMP Detector Type Metadata
The eStreamer service transmits metadata containing FireAMP detector type 
information for an event within a FireAMP Detector Type record, the format of 
which is shown below. (FireAMP detector type information is sent when one of 
the metadata flags—bits 1, 14, 15, or 20 in the Request Flags field of a request 
Byte
0
1
2
3
Bit
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Header Version (1)
Message Type (4)
Message Length
Record Type (129)
Record Length
Malware Event Subtype ID
Malware Event Subtype Length
Malware Event Subtype...
Malware Event Subtype Record Fields 
F
IELD
D
ATA
 
T
YPE
D
ESCRIPTION
Malware Event 
Subtype ID
uint32
The malware event subtype ID number.
Malware Event 
Subtype Length
uint32
The number of bytes included in the malware 
event subtype.
Malware Event 
Subtype
string
The malware event subtype.