Cisco Cisco Packet Data Gateway (PDG)

Pagina di 5133
  show card 
  ▀   
 
Statistics and Counters Reference, StarOS Release 16   ▄  
 
   
3669 
Field
 
Applicable 
Card(s)
 
Description
 
Card LEDs 
All (except as 
indicated) 
Displays the state of the Run/Fail, Active and Redundancy light emitting 
diodes (LEDs) on the front panels of each of the cards. 
 
Run/Fail LED: Green is normal, Red or Off indicate a problem. 
 
Active: Green indicates that the software is loaded or is being 
loaded (blinking) on the card. 
 
Redundancy: Green indicates that the card is in standby mode. 
NOTE: If the Run/Fail LED is either Red or Off, refer to ASR 5500 System 
Administration Guide
 for information on troubleshooting the problem. 
The following LEDs appear on the MIO/UMIO only: 
 
Master: Green indicates that the card is in Active mode. 
 
Busy: Green indicates that the card is accessing the RAID solid 
state drives on the FSCs. 
The following LEDs appear on the FSC only: 
 
Drive 1 Activity and Drive 2 Activity: Indicate that the RAID 
solid state drives are being accessed by the MIO/UMIO. 
The following LEDs appear on the SSC only: 
 
System Status: Red indicates the that there is a loss of service 
somewhere in the system. For example, the system could not 
locate a a valid software image at boot-up, or a high temperature 
condition exists. 
 
System Service: Illuminates amber to indicate that the system has 
experienced a hardware component failure. 
Refer to the ASR 5500 Installation Guide for additional information. 
CPU 0, CPU 1 
MIO/UMIO, 
DPC/UDPC 
Displays whether an Error ID Log or Boot Progress Log is present for the 
CPU. 
 
show card info (QvPC-SI) 
Table 233. 
show card info (QvPC-SI)
 Command Output Descriptions 
Field
 
Applicable 
Card(s)
 
Description
 
Slot Type 
Virtual 
Displays the acronym for the card type. 
Card Type 
Virtual 
Indicates the type of card installed.