Cisco Cisco Content Delivery Engine 250 Guida All'Installazione

Pagina di 14
 
 
      Please wait for a positive acknowledge from the utility prior to rebooting.  
 
      
Please DO NOT power-cycle and/or interrupt the firmware upgrade process. 
      Doing so may result in the system being placed into a non-recoverable state. 
 
7)   After the IPMI firmware upgrade completes, you must power-cycle the system. 
 Of course, be sure to first remove the USB DOS stick prior to power-cycling. 
 
2.3 IPMI  Firmware  Upgrade  Process  using  the  dedicated 
IPMI Ethernet port 
 
1.  Download the IPMI v3.03 firmware files to a remote desktop: 
a.  For VDS-TV these are contained in the ipmi303.zip downloaded from the 
“Download Link for IPMI FW v3.03 for VDS-TV Application” link contained in 
FN #63883: 
i.  Unzip ipmi303.zip to a temporary folder 
ii.  Note the location of the temporary folder 
 
 
 
b.  For VDS-IS these are contained in the vdsis-ipmi303.zip downloaded from the 
“Download Link for IPMI FW v3.03 for VDS-IS Application” link contained in 
FN#63883: 
i.  Unzip vdsis-ipmi303.zip to a temporary folder 
ii.  Note the location of the temporary folder 
 
c.  For VQE these are contained in the IPMI303.zip downloaded from the 
“Download Link for IPMI FW v3.03 for VDS-IS Application” link contained in 
FN#63883: 
i.  Unzip IPMI303.zip to a temporary folder 
ii.  Note the location of the temporary folder 
 
2.  Configure the dedicated Ethernet port of the CDE250 in the system BIOS, if already 
configured skip to step 3. 
a.  Reboot the CDE250 system  
b.  Press the <DEL> key during post to enter the BIOS setup utility 
c.  Select the “IPMI Configuration” 
d.  Set your IPAddress and attributes 
e.  Press <ESC>, the press <CNTL><F10>, the save and exit 
 
3.  Connect an Ethernet cable to the IPMI port and to your management network