Cisco Cisco Content Delivery Engine 250 Guida All'Installazione

Pagina di 14
 
 
10 
 
2.3.2 Validation on CDS-TV 
Verify the IPMI FW using the following command: 
CDE250_Streamer# cat /sys/devices/platform/ipmi_bmc.aabb.32/firmware_revision 
This should return “3.9” 
Note: Linux will usually strip the “0” from the 3.09 string. 
Execute the “sdt” CLI command.  Verify this command does not hang (example output is 
shown below): 
CDE250_Streamer# sdt 
 
***************************************************************************** 
 SuperDoctor II - Linux version 2.111(140922) 
 Copyright(c) 1993-2014 by Super Micro Computer, Inc. http://supermicro.com/ 
***************************************************************************** 
Monitored Item            High Limit  Low Limit     Status 
---------------------------------------------------------------------- 
Fan1 Fan Speed                              715       7031 
Fan7 Fan Speed                              715       5625 
Power1 Fan 1 Speed                         4007       7786 
Power1 Fan 2 Speed                         4007      12251 
Power2 Fan 1 Speed                         4007       8129 
Power2 Fan 2 Speed                         4007      12137 
CPU1 Vcore Voltage              1.49       0.60       1.06 
CPU2 Vcore Voltage              1.49       0.60       1.20 
CPU1 VTT Voltage                1.34       0.92       1.13 
CPU2 VTT Voltage                1.65       0.92       1.13 
CPU1 DIMM Voltage               1.65       1.20       1.36 
CPU2 DIMM Voltage               1.65       1.20       1.37 
+1.5V Voltage                   1.65       1.35       1.45 
+1.8V Voltage                   1.98       1.62       1.78 
+5V Voltage                     5.50       4.51       5.02 
+12V Voltage                   13.19      10.80      12.13 
+1.1V Voltage                   1.21       0.98       1.10 
+3.3V Voltage                   3.65       2.95       3.29 
+3.3Vsb Voltage                 3.65       2.95       3.24 
VBAT Voltage                    3.65       2.95       3.00 
CPU1 Temperature              95/203                   Low 
CPU2 Temperature              95/203                   Low 
System Temperature            75/167                 37/98 
Power1 Temperature            80/176                 37/98 
Power2 Temperature            80/176                38/100 
Chassis Intrusion                                     Good 
Power Supply Failure                                  Good 
Power1 Supply Failure                                 Good 
Power2 Supply Failure                                 Good 
--------------------------------------------- Fri Mar 20 13:08:12 2016