Cisco Laser Link Return Digital Receiver with Ethernet Guida All'Installazione

Pagina di 53
78-4028521-01 Rev B 
Installation 
2-7 
Laser Link III Mainframe Electrical Connections,
 Continued 
Power Distribution Board Connectors 
Interfaces J1 through J7 (A and B) provide the connection points for housed modules 
to the mainframe.  Individual module manuals describe the pins utilized for each 
module.  Status monitoring (J12), EMIC (J8), primary power (J10) and telemetry 
connection points (J9A and J9B) are labeled on the board.  The terminal block (J11) 
provides connection for the +24 V DC redundant input and for the alarm relay 
contacts.  Alarm relays may be used to trigger external alarming systems. 
 
 
Important:  Wire gauge specifications for 24 V DC/15 A input are as follows: 
10’ cable:  12 AWG minimum 
5’ cable:  15 AWG minimum