Cisco Cisco Computer Telephony Integration OS 8.5 Guida Dello Sviluppatore
3-3
CTI OS Developer’s Guide for Cisco Unified ICM/Contact Center Enterprise & Hosted
Release 8.0(1)
Chapter 3 CIL Coding Conventions
CIL Error Codes
To determine the success or failure of the underlying telephony operation requested, the CTI
programmer must wait for an event confirming the success or failure of the request. To generalize the
message flow model, most requests made at the CTI OS CIL will be answered with a confirmation
message and/or an event message. See the object interface reference in Chapters 8-12 for details on each
particular request. This type of response is called asynchronous – it can arrive at any time after the
request is made, but typically requests are services in sub-second timeframes.
programmer must wait for an event confirming the success or failure of the request. To generalize the
message flow model, most requests made at the CTI OS CIL will be answered with a confirmation
message and/or an event message. See the object interface reference in Chapters 8-12 for details on each
particular request. This type of response is called asynchronous – it can arrive at any time after the
request is made, but typically requests are services in sub-second timeframes.
For each method request in the programmer’s interface sections of this document, the expected event
sequence is described, so that programmers know which events to expect. In the event of a request
failure, an eControlFailureConf message will be send to the client; the eControlFailureConf message
will have a parameter called MessageType indicating which request failed, and a parameter called
ErrorMessage, with a description of the failure cause.
sequence is described, so that programmers know which events to expect. In the event of a request
failure, an eControlFailureConf message will be send to the client; the eControlFailureConf message
will have a parameter called MessageType indicating which request failed, and a parameter called
ErrorMessage, with a description of the failure cause.
For example: when sending a MakeCall request, the method will typically return CIL_OK, which means
that the method call was successful. If the underlying make call request is successful, the CIL will
receive several follow-on events, such as eBeginCallEvent and eServiceInitiatedEvent. If the request
fails, the CIL will receive the eControlFailureConf message.
that the method call was successful. If the underlying make call request is successful, the CIL will
receive several follow-on events, such as eBeginCallEvent and eServiceInitiatedEvent. If the request
fails, the CIL will receive the eControlFailureConf message.
A common mistake: developers who have not previously programmed with asynchronous events might
mistake the error code returned from a method call for the actual result of the request. The correct
semantics are to interpret the error code as being indicative of the result of the method call, and to
interpret the follow-on events to determine the actual result of the requested operation.
mistake the error code returned from a method call for the actual result of the request. The correct
semantics are to interpret the error code as being indicative of the result of the method call, and to
interpret the follow-on events to determine the actual result of the requested operation.
CIL Error Codes
Whenever a method call is invoked by a custom application using the CIL, an error code is returned. The
error codes returned only indicate success or failure of the method call, as indicated in the previous
section.
error codes returned only indicate success or failure of the method call, as indicated in the previous
section.
The possible values of the error code returned from C++ and Java CIL methods are defined in
.
Note
The numeric values listed in Table 3-2 are subject to change. It is recommended that you use the error
code enumerations to check a given error code, rather than rely on a specific numeric value.
code enumerations to check a given error code, rather than rely on a specific numeric value.
Table 3-2
CIL Error Codes
CIL Error Code
Numeric
Value
Description
CIL_OK
1
The method succeeded. The request to silent monitor the call was
successfully initiated.
successfully initiated.
CIL_FAIL
0
The method failed.
E_CTIOS_METHOD_NO_
IMPLEMENTED
IMPLEMENTED
-99
There is no implementation available for this method.
E_CTIOS_INVALID_
PROPERTY
PROPERTY
-100
One or more properties are invalid.
E_CTIOS_MODE_CONFLICT
-101
A conflict when setting session mode.
E_CTIOS_INVALID_ EVENTID
-102
The Event ID is not valid.
E_CTIOS_INVALID_
ARGUMENT
ARGUMENT
-103