Cisco Cisco FirePOWER Appliance 8270
51-25
FireSIGHT System User Guide
Chapter 51 Configuring Appliance Settings
Enabling Cloud Communications
.
For example, to display a list of appliance information, the IPMItool command is:
ipmitool -I lanplus -H
IP_address
-U
user_name
sdr
Note
Cisco recommends using IPMItool version 1.8.12 or greater.
The same command with the IPMIutil utility is:
ipmiutil sensor -V 4 -J 3 -N
IP_address
-U
user_name
To use Lights-Out Management:
Access:
Admin with LOM access
Step 1
Enter the following command:
For IPMItool:
ipmitool -I lanplus -H
IP_address
-U
user_name
command
Note
Cisco recommends using IPMItool version 1.8.12 or greater.
For IPMIutil:
ipmiutil -J 3 -H
IP_address
-U
username
command
where
command
is one of the commands from the
table.
The corresponding action as noted in the table is performed. You may be prompted to enter a password.
Enabling Cloud Communications
License:
URL Filtering or Malware
Table 51-6
Lights-Out Management Commands
IPMItool
IPMIutil
Description
(not applicable)
-V 4
Enables admin privileges for the IPMI session
-I lanplus
-J 3
Enables encryption for the IPMI session
-H
-N
Indicates the IP address of the remote appliance
-U
-U
Indicates the username of an authorized LOM account
sol activate
sol -a
Starts the SOL session
sol deactivate
sol -d
Ends the SOL session
chassis power cycle
power -c
Restarts the appliance (not valid on 70xx Family devices)
chassis power on
power -u
Powers up the appliance
chassis power off
power -d
Powers down the appliance (not valid on
70xx Family devices)
sdr
sensor
Displays appliance information, such as fan speeds and
temperatures
temperatures