System Exclusive Data
Page C contains Multi parameters 
and Global parameters. These 
parameters are sent and received 
only by SysEx Parameter Change.
In the following, all bytes are 
shown in hexadecimal representa-
tion.
Control Change message 
(only Page A)
Bc
Status byte, 
c=MIDI channel 
nn
Parameter Number 0..127
(see parameter list Page A) 
vv
Parameter Value  0..127
see parameter list Page A)
 
The Control Change messages 
are defined as Performance Con-
troller (e.g. Modulation Wheel or 
Hold Pedal) or Sound Parameters 
(e.g. Cutoff or Patch Volume). The 
Performance Controllers are not 
stored with a Single-Sound. If more 
than one Multi Part is set to the 
same MIDI channel, all Parts on this 
MIDI channel receive the same Per-
formance Controllers. The Sound 
Parameters are stored with a Single 
Sound. If more than one Multi Part 
is set to the same MIDI channel, the 
Sound Parameter is receiced only by 
the Multi Part with the lowest part 
number.
Example: B0,21,40 Set oscillator 
balance (21 hex = 33 dec) on MIDI 
channel 1 to the middle position 
(40 hex =64 dec).