Access virus os4 Manuale Utente
254
CHAPTER
24
Appendix
Polyphonic Pressure message
(only Page B)
(only Page B)
Ac
Status byte, c=MIDI channel
nn
Parameter Number 0..127
(see parameter list Page B)
(see parameter list Page B)
vv
:Parameter Value 0..127
see parameter list Page B)
see parameter list Page B)
Example: A2,07,25 Control LFO3
Rate on MIDI channel 3 (!).
Rate on MIDI channel 3 (!).
System-Exclusive-Message
F0
Start of System Exclusive
00
Manufacturer ID 1
Access Music Electronics
Access Music Electronics
20
Manufacturer ID 2
Access Music Electronics
Access Music Electronics
33
Manufacturer ID 3
Access Music Electronics
Access Music Electronics
01
Product ID (Virus)
dd
Device ID
00..0F individual; 10: omni.
...
...
[message]
F7
End of System Exclusive
SysEx Parameterchange
[message]=
7x
7x
Parameterchange
70:page A;
71:page B;
72:page
70:page A;
71:page B;
72:page
C pp Part number
00..0F Multi part 1..16;
40: Single
40: Single
nn
Parameter Number
0..127 (see parameter list)
0..127 (see parameter list)
vv
Parameter Value0..127
(see parameter list)
(see parameter list)
{F0,00,20,33,01,dd,7x,pp,nn,vv,F7}
The SysEx Parameterchange
affects one of the sixteen single edit
buffer in Multi Mode addressed by
the part number (00..0F) or the Sin-
gle buffer in Single Mode (part
number 40). If a global parameter
or a Multi parameter is accessed,
which is not part-sensitive (e.g.
Input Boost or Multi Delay Time),
the part number is ignored.
buffer in Multi Mode addressed by
the part number (00..0F) or the Sin-
gle buffer in Single Mode (part
number 40). If a global parameter
or a Multi parameter is accessed,
which is not part-sensitive (e.g.
Input Boost or Multi Delay Time),
the part number is ignored.
Example:
F0,00,20,33,01,10,70,05,28,5F,F7
Set Cutoff on Part 6 to decimal
F0,00,20,33,01,10,70,05,28,5F,F7
Set Cutoff on Part 6 to decimal