ADC higain h2tu-c-319 list 4e Manuale Utente

Pagina di 88
LTPH-UM-1049-02, Issue 2
 
Appendix A - Specifications
H2TU-C-319 List 4E
January 9, 2002
 69
 shows the generic labeling of the connector as it appears on the backplane with HMS-358 shelf. Note 
that the H2TU-C has no connections to Loop B of Group 1. The HMS-358 technical practice refers to Group 1 
and Group 2 as Port 1 and Port 2, respectively.
Figure 34.
HMS-358 Backplane H2TU-C-319 List 4E Card Edge Connector Labeling
Network Management Control Bus
The H2TU-C provides a Network Management Control Bus on pin 7 of the card-edge connector. This allows the 
various ADC Management System protocols to manage the H2TU-C through the HMU-319 HiGain Management 
Unit. Whenever the H2TU-C is under management, the 
MNGD
 message displays periodically on the front-panel 
display.
Fuse Alarm
Pin 10 on the card-edge connector is a Fuse Alarm that is driven to -48 Vdc through a diode whenever its onboard 
fuse opens. It emulates the function of the Fuse Alarm output from pin 10 on normal, high density (HD) repeaters. 
pin 10 is connected to pin 5 of the 1184 Alarm Card (slot 1 in the HD shelf) and causes the 1184 Fuse ALM LED 
to light when the pin 10 signal is activated. Its normally floating output must never be driven above ground or 
below -80 Vdc. It can sink a current of 10 mA. The H2TU-C does not support the BPV function (pin E) of normal 
HD repeaters.
Some H2TU-C features are affected when it is under management. Consult the management unit 
practice for further information.
3192 MECH
Group Port 2
Group Port 2
Group Port 1
Group Port 1
21
19
20
21
22
22
23
23
24
24
25
25
26
26
27
28
29
3
1
AUX (Loop A) Ring
AUX (Loop A) Tip
AUX (Loop B) Ring
AUX (Loop B) Tip
2
3
1
A
DSX (XMT from MUX) Tip
DSX (XMT from MUX) Ring
DSX (RCV to MUX) Tip
DSX (RCV to MUX) Ring
Line (Loop A) Tip
Line (Loop A) Ring
Line (Loop B) Tip
Line (Loop B) Ring
4
4
2
B
5
5
3
C
6
6
4
D
7
7
5
E
8
8
6
F
9
7
10
8
H
11
9
J
10
K
L