HP mhp-tn Manuale Utente

Pagina di 28
MHP-TN USER INSTRUCTIONS ENGLISH 71576313 - 02/07
Page 25 of 28
flowserve.com
7 FAULTS; CAUSES AND REMEDIES
Insufficient flow rate
Irregular pump running
Driver overloaded
Mechanical seal leak
Equipment vibration
Excessive pump casing temperature
POSSIBLE CAUSES
SOLUTIONS
 
  Pump or suction pipe not completely filled
- Check and complete filling
 
Air bubbles in pipes
- Check and desecrate the pipes
  Suction level too low
- Check: the available NPSH > the required NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings (diameter increase
and appropriate fitting positions)
- Check valves and strainers
- Check the immersion head of the suction valve
 Wrong rotation
- Reverse 2 phases on motor terminal boxes
  
The motor is running on 2 phases only
- Check and control the motor electrical power supply
Motor running too low
- Check the connection in the terminal box according to the
voltage
Total manometric head system higher than
pump differential head
- Check the discharge head
- Check the head losses in discharge pipes (partly closed valve,
foreign particles, back pressure too high)
- Modify the installation or change the pump set
Total manometric head system lower than
pump differential head
-Throttle at discharge valve or trim the impeller (contact our
local agent): CONSULT FLOWSERVE
  Pipes (valves, filter...)
- Control, dismantle and clean
  Insufficient flow rate
- Check the suction and discharge pipes (valves, back
pressure)
Worn wear-ring surfaces
- Foresee pump mending. CONSULT FLOWSERVE
   
Seizure, jamming
- CONSULT FLOWSERVE
   
Excessive strains on flanges
- Check the flange connections and eliminate strains (pipe
positioning or elastic sleeves mounting)
Defective gland packing on the shaft
- Check and replace all the gland-packing parts.
- Mechanical seal: CONSULT FLOWSERVE
   
Defective motor bearings
- CONSULT FLOWSERVE
 Specific gravity or viscosity of liquid too high
- Consult our local agent to analyze the problem
Misalignment
- Check the alignment of the pump and of its driver
Foundations not sufficiently rigid
- Check the setting of base plates: tightening, bad adjustment,
seal
Insufficient pressure
Pump looses prime after starting
POSSIBLE CAUSES
SOLUTIONS
Rotation speed too low (check the driver)
- Check the connection in the terminal box according to the
voltage
  Presence of air
- Check and de-aerate
Suction pressure insufficient
- Check: the available NPSH > the required NPSH
Mechanical defects
- CONSULT FLOWSERVE
 Air leak in the suction pipe
- Check suction pipe is airtight
 Restriction in suction pipe
- Check diameter of suction pipe
 Suction level too low
- Check the NPSH >NPSH
- Reduce geometrical suction lift
- Reduce head losses in pipes and in fittings (diameter increase
and appropriate fitting positions)
- Check valves and strainers
- Check the immersion head of the suction valve
 Obstruction of suction pipe
- Check condition of pipe
 Defective gland packing on the shaft
- Check and replace all the gland packing.
- Mechanical seal: CONSULT FLOWSERVE
 Defective gasket
- CONSULT FLOWSERVE