HP omnibook 2000_5500_5700 Manuale Di Servizio

Pagina di 119
35
Valid Keystrokes
Action
n/a
The ROM test ignores the keyboard.
Failure Message
Error Code
Meaning
User Aborted
1
User aborted test.
PCMCIA - 
(PCMCIA.COM)
The PCMCIA test sets up the TI CardBus controller chip, tests IRQ 3, and restores the chip.
DOS Parameter
Explanation
0
Test lower slot
1 (or any non-0 value)
Test upper slot
Valid Keystrokes
Action
n/a
The PCMCIA test ignores the keyboard.
Failure Message
Error Code
Meaning
User Aborted
1
User aborted test.
Failed
2
IRQ fail
Internal IR - 
(FIRTEST.EXE)
This test performs a minimal test of the IR chip but does not require a second OmniBook.  The
Full 2 Unit IR test is a more thorough test and does require a second OmniBook (see next
section).
DOS Parameter
Explanation
Internal
Performs the internal (standalone) test.
Valid Keystrokes
Action
n/a
The Internal IR test ignores the keyboard.
Failure Message
Error Code
Meaning
Must clean boot
1
CPU protected mode bit set,
must clean boot.
Must undock
3
This test cannot run while
docked.  Can also get this
error if the internal transmit
failed.
Failed
5
Receive fail or any other fail.