HP omnibook 2000_5500_5700 Manuale Di Servizio

Pagina di 119
37
the 3 speeds under test.  Default = 3.
Phytest
Limits the test to just one speed which can
be set with /BAUD.  It also uses all null
bytes rather than random data.  Default
speed = 115200 baud
Valid Keystrokes
Action
any key
Any keystroke will abort The Full 2 Unit IR
test.
Failure Message
Explanation
OK
The test passed.
Must clean boot
A clean boot is required prior to the test
(see step 1 above).
User abort
The test was aborted.
Must undock
The test cannot run when the OmniBook is
docked.
No reflector unit
The computer under test did not receive
back any of the packets it transmitted.
Either the known good computer is not
positioned properly or is not running the test
(see step 2 above).
Fail
The test failed.
RS-232 Port - 
(RS232.COM)
N
OTE
:
This test requires a serial loopback connector to be connected to the serial
port.
The RS-232 Port test reads/writes to the COM1 serial port IER, baud divisor registers, and LCR.
It also checks for the loopback connector and sends a byte through the loopback connector at
each of the baud rates.  The RS-232 Port test is hardcoded to test the UART at 3F8, therefore, it
can test only COM1.
DOS Parameter
Explanation
none
Valid Keystrokes
Action
n/a
The RS-232 test ignores the keyboard.
Failure Message
Error Code
Meaning
User Aborted
1
User aborted test.
Failed
2
No loopback connector
No loopback
3
Sending bytes failed
No loopback
4