Software Management
Xmodem Download From a PC or Unix Workstation
This procedure assumes that:
The switch is connected via the Console RS-232 port on a PC operating as a terminal. (Refer to 
the Installation Guide you received with the switch for information on connecting a PC as a 
terminal and running the switch console interface.)
The switch software is stored on a disk drive in the PC.
The terminal emulator you are using includes the Xmodem binary transfer feature. (For example, 
in the Windows NT terminal emulator, you would use the 
Send File option in the Transfer dropdown 
menu.)
Syntax:copy xmodem flash <unix | pc>
For example, to download a software file from a PC:
1.
To reduce the download time, you may want to increase the baud rate in your terminal emulator 
and in the switch to a value such as 57600 bits per second. (The baud rate must be the same in 
both devices.) For example, to change the baud rate in the switch to 57600, execute this 
command:
HP2512(config)# console baud-rate 57600
 
(If you use this option, be sure to set your terminal emulator to the same baud rate.)
2.
Execute the following command in the CLI:
3.
Execute the terminal emulator commands to begin the Xmodem transfer.
The download can take several minutes, depending on the baud rate used in the transfer.
When the download finishes, the switch automatically reboots itself and begins running the new 
software version.
4.
To confirm that the software downloaded correctly:
HP2512> show system
Check the 
Firmware revision line.
5.
If you increased the baud rate on the switch (
previous setting. (HP recommends a baud rate of 9600 bits per second for most applications.)
(Remember to return your terminal emulator to the same baud rate as the switch.)