01X   Owner’s Manual
Troubleshooting
■ Pairing was specified, but the signal phase 
does not match.
• Even when channels are paired, 
the phase setting is not linked. ................................ page 102
■ Automation (Automix) cannot be stopped.
• Has the REMOTE AUTOMATION SETUP 
parameter been set to correctly? ............................... page 88
■ Can’t use the internal effects.
• Effect BYPASS may be turned ON......................... page 102
• Are the level of STEREO IN 1, 2 faders raised?........ page 99
• EFFECT PATCH may be set to 
insertion (each channel).......................................... page 102
• It is not possible to insert one effect 
into multiple channels. ........................................... page 102
• 019. HQ. Pitch can be used only with EFFECT 1.
• When the sampling rate is 96kHz/88.2kH, only Effect 1 can be 
used.
■ Can’t use SOLO.
• The channel may be set to Solo Safe......................... page 96
■ Fader groups and mute groups don’t work.
• In the Fader Group page and Mute Group page, 
check that grouping is set to ENABLE. .................. page 101
■ The pitch is wrong.
• Is the 01X operating on the same sampling frequency 
as the synchronized external device?
......... page 92, “Connecting a Computer to an mLAN 
device via mLAN” (Installation Guide), “mLAN Con-
nection Settings” (Graphic Patchbay Online Manual)
• Is the master device operating in a stable way?
• Is an effect such as HQ.Pitch or 
Dual Pitch selected? ............................................... page 102
■ The layer of 17-24 (mLAN9-16) cannot be 
used.
• When the sampling rate is set to 96kHz/88.2kHz, 
the layer of 17 – 24 (mLAN) can not be selected. ..... page 40
■ Cannot edit with Studio Manager.
• Has the STUDIO MANAGER ID 
been set correctly?.................................................... page 94
• Is Port 4 (Studio Manager) selected for 
Studio Manager data transmission/reception?
.......................... Studio Manager Owner’s Manual (PDF)
■ The Remote Control or Automation 
features do not work.
• Is the correct DAW software selected in Remote Select?
........ page 87, “Demo playback/Remote Control Setup”  
(Installation Guide)
• Are the mLAN settings correct?
.........“Demo playback/Remote Control Setup” 
(Installation Guide)
• Are settings on the DAW correct?
.........page 87, “Demo playback/Remote Control Setup” 
(Installation Guide)
• Is Port 1 selected for mLAN MIDI transmission/reception?
.........page 87, “Demo playback/Remote Control Setup” 
(Installation Guide)
■ Cannot change the wordclock.
• Set this with the mLAN Auto Connector or 
Graphic Patchbay when using mLAN.
.........“Connecting a Computer to an mLAN device via 
mLAN” (Installation Guide),  “Wordclock Settings” 
(Graphic Patchbay Online Manual)
• Is the mLAN Auto Wordclock (AUTO W.CLK) 
setting appropriate?
.........“Connecting a Computer to an mLAN device via 
mLAN” (Installation Guide)
■ The mLAN connection does not work.
• Has the driver been installed? .................... Installation Guide
• Is the mLAN cable properly connected?  Check the connec-
tion; disconnect the mLAN cable once, then insert it again.
• (For Windows) Is mLAN set to “ON”?  From the taskbar, 
right click on the mLAN Manager icon.
.........“Confirming the installation” (Installation Guide)
• (For Windows) When adding a new IEEE 1394 card, right click 
on the mLAN Manager icon in the taskbar and select “ON.”.
.........“Confirming the installation” (Installation Guide)
• Is the ACTIVE lamp on the rear panel of the 01X lit (in blue)?  
If it is not lit, check the followings:
• In mLAN Driver Setup (from taskbar, right click on the mLAN 
Manager icon, then “Driver Setup”), is the Status indicator 
blue?  If not, restart the 01X and re-enable connection by using 
mLAN Auto Connector or Graphic Patchbay.
.........“Confirming the installation” (Installation Guide), 
Graphic Patchbay Online Manual
• Is mLAN AUTO W.CLK (Auto Wordclock) 
on the 01X set to “ENABLE”?
.........“Connecting a Computer to an mLAN device via 
mLAN” (Installation Guide)
• Has connection been enabled with mLAN 
Auto Connector or Graphic Patchbay?  
Re-enable connection if necessary.
.........“Connecting the Computer and mLAN devices via 
mLAN” (Installation Guide), “mLAN Connection 
Settings” (Graphic Patchbay Online Manual)
• Have you changed the device?  Even if the model is the same, 
if the actual device is different, it is necessary to re-enable con-
nection by using mLAN Auto Connector or Graphic Patchbay.
.........“Connecting the Computer and mLAN devices via 
mLAN” (Installation Guide), “mLAN Connection 
Settings” (Graphic Patchbay Online Manual)
• Is there a loop connection?  Check the cabling and make sure 
none of the devices are connected in a loop.
Computer
Computer
01X
01X
: IEEE 1394-equipped device
Example of loop connection