therma-stor-products-grou ts-261b Manuale Utente

Pagina di 11
7
www.thermastor.com • sales@thermastor.com
Toll-Free 1-800-533-7533
4.  Remove the cable clamp holding the impeller fan cable 
and ground terminals. Remove the ground wire from 
the mounting screw. Disconnect the black and brown 
wires from the run capacitor, and cut the blue wire 
near the wire nut.
5.  Remove the /4” machine screws holding the base to  
the cabinet. Remove the base from the cabinet.
6.  Remove the four 4 mm machine screws that hold the  
motor to the lower base. Remove the cable clamp that  
holds the impeller fan cable to the bottom of the base.
7.  Remove the strain relief 
bushing holding the 
impeller fan cable in the 
top of the base.
4 Service
CAUTION: Servicing the Phoenix Mini-Guardian HEPA 
System with its high voltage circuitry presents a health 
hazard that could result in death, serious bodily injury, and/
or property damage. Only qualified service people should 
service this unit.
4.1 Warranty
A warranty certificate has been enclosed with this unit. 
Read it before any repair is initiated. If a warranty repair 
is required, call the factory first at -800-533-7533 for 
warranty claim authorization and technical assistance.
4.2 Impeller Fan Replacement
Occasionally the impeller fan may not start on low speed. If 
this occurs, rotate the speed control to high speed until the 
impeller fan starts, then adjust it to low speed.
Follow the steps below to change the impeller fan:
.  Unplug the power cord.
2.  Remove the top and all air filters.
3.  Remove the rear electrical guard held inside the unit  
by four mm machine screws and nuts.
Figure 12: Remove guard
Figure 13: Remove cable clamp
Figure 15: Remove strain relief
Figure 14: Remove screws
Clamp 
Cable
Cut near 
wire nut
Clamp 
cable 
inside
4 mm 
screws