Adam Equipment 302666242 Manuale Utente

Pagina di 44
 
© Adam Equipment Company 2011 
Page  
19
 
 
6.4  PLU  (Product Look Up) 
 
Product  Look-Up  (PLU)  numbers  are  used  to  store  information  about  the 
commonly used items. The Tare Weight, Description of the product and Unit 
Weights  for  a  particular  item  are  recalled  by  entering  the  PLU  number  for 
ease of operation.  
 
The  scale  is  capable  of  storing  values  for  the  Tare  weight,  Description  and 
Unit Weight for a maximum of up to 100 PLU numbers.   
 
Tare  Weight  value  is  required  for  calculating  the  Net  Weight  where  a 
container  is  used  during  weighing.  Descriptions  are  used  for  sending  data 
over  RS-232  for  viewing  or  printing  and  Unit  Weight  is  used  for  parts 
counting.  
 
These  data  should  be  entered  against  a  particular  PLU  before  the 
weighing  process  starts  so  that  the  desired  PLU’s  can  be  recalled 
during  the  weighing  process.  The  data  can  be  stored  and  recalled 
manually or by sending data over RS-232 Interface. 
 
6.4.1 STORING  PLU’S MANUALLY 
 
 
DISPLAYS 
ACTIONS 
Weight  Unit weight  Count 
REMARKS 
 
Press [Tare/Zero] 
if required. 
 
“O.0000”       “     0“        
“         0“ 
The scale is 
zeroed. 
 
Note: 
 
Enter  or  determine  the  Tare  Weight  when  a  container  is  to  be  used  (see 
section 6.2 of this User Manual). If a Tare value is used, the scale will be in 
the NET mode. 
 
Enter or determine the Unit Weight as described in section 6.3.1 and 6.3.2 of 
this User Manual. 
 
The Tare and Unit Weight to be stored can be either taken from a weighing in 
process or by manual entry of data.