6.3.2 Entering a known Unit Weight 
 
  If  the  unit  weight  is  already  known  then  it  can  be  entered  using  the 
keypad.  
 
 
  Enter  the  value  of  the  unit  weight  using  the  numeric  keys  followed  by 
pressing  the  [U.  Wt.]  key  within  few  seconds  while  the  display  is 
flashing. If no action is initiated within a few seconds, the "Unit Weight” 
display will revert to the previous value, otherwise it will show the new 
value that has been entered.  
 
  The sample is then added to the scale and the weight will be displayed 
as  well  as  the  quantity  based  upon  the  unit  weight.  When  weighing  in 
kilograms the unit weight is shown in grams.  When weighing in pounds 
the unit weight is shown in pounds. 
 
  After the unit weight has been determined or entered, the scale can be 
used for parts counting. The scale may be tared to account for the net 
weight as discussed in an earlier section.  
 
  After  the  scale  is  tared,  the  items  to  be  counted  are  added  and  the 
"Count"  display  will  show  the  number  of  items  computed  using  the 
weight and the unit weight. 
 
  It  is  possible  to  increase  the  accuracy  of  the  unit  weight  at  any  time 
during  the  counting  process  by  manually  entering  the  sample  quantity 
and  then  pressing  the  [Smpl]  key.  You  must  ensure  that  the  quantity 
displayed  matches  the  quantity  on  the  scale  before  pressing  the  key. 
The  unit  weight  will  be  adjusted  based  upon  a  larger  sample  quantity. 
This will give greater accuracy when counting larger sample sizes. 
 
 
6.3.3 Automatic update of unit weight  
 
  The scales will automatically update the unit weight when a sample less 
than  the  initial  sample  count  is  added.  A  beep  will  be  heard  when  the 
value is updated. It is wise to check the quantity is correct when the unit 
weight has been updated automatically. 
 
  To lock the unit weight and prevent Auto-update, press [U.Wt.]. 
 
  This  feature  is  turned  off  as  soon  as  the  number  of  items  added 