Epson CX11N Manuale Utente

Pagina di 16
Epson AcuLaser CX11N/CX11NF
14
 -
 Epson AcuLaser CX11N/CX11NF
8/05
Caution: 
Do not touch the belt on the top of the photoconductor or the 
blue area; otherwise, print quality may decrease.
Avoid exposing the photoconductor to light any longer than 
necessary. 
Do not touch any other components inside the CX11N.
9. Hold the photoconductor by its handle and insert it into 
the slots marked with blue arrows inside the CX11N. Push 
it in until it clicks into place.
Warning: 
Be careful not to touch the fuser, which is marked CAUTION 
HIGH TEMPERATURE. If you have been using the CX11N 
recently, the fuser may be very hot.
10. Flip down the orange lever, then close cover B.
11. Slide out and flip open the output tray extension, if 
necessary.
12. Slowly push down the scanner to its original position. 
Cleaning the CX11N
If the CX11N’s outer case is dirty or dusty, turn off the 
CX11N and clean it with a soft cloth moistened with mild 
detergent.
Caution: 
Never use alcohol or paint thinner to clean the CX11N; these 
chemicals can damage the components and the case. Be careful not 
to get water on the CX11N mechanisms or any electrical 
components.
Cleaning the Pickup Roller
1. Make sure the CX11N is turned off and that the power cord 
is not plugged into an outlet. 
2. Open the MP tray cover and remove any loaded paper.