Setting the unit as CO/CPE
23
Model 3231 User Manual 
2 • Initial Configuration
Setting the unit as CO/CPE
Configuring the unit as CO
To set the unit as CO:
1. From the top level menu on the LCD panel, use the Left and Right arrow keys to navigate to G.SHDSL
and press ENTER
2. Use the arrow keys to highlight Mode, then press ENTER
3. Select CO, and press ENTER
4. To activate the unit as CO, select Restart DSL from the G.SHDSL menu, and press ENTER. 
The CPE LED on the front panel should not be lit. 
Configuring the unit as CPE
To set the unit as CPE:
1. From the top level menu on the LCD panel, use the Left and Right arrow keys to navigate to G.SHDSL
and press ENTER
2. Use the arrow keys to highlight Mode, then press ENTER
3. Select CPE, and press ENTER
4. To activate the unit as CPE, select Restart DSL from the G.SHDSL menu, and press ENTER. 
The CPE LED on the front panel should be lit. 
Note
Do not use the CPE Config options in the LCD menu on the CPE unit for 
CPE configuration. Use the Model 3231 that you set as the CO to configure 
the CPE unit. See 
 on page 21 for CPE configuration options.