Runco plasmawall xp-65dhdxa Manuale Utente

Pagina di 70
36
PlasmaWall XP-65DHD Owner’s Operating Manual
PRE
L
IMINAR
Y
Sharpness: “Sharpness” is the amount of high-frequency detail in the image. To adjust 
sharpness, select Sharpness from the Picture menu and press ENTER. On your external 
test pattern source, select a pattern like the one shown in Figure 4-5. Adjust as needed, 
looking for white edges around the transitions from black to gray and differently-sized lines 
in the “sweep” patterns at the top and bottom. Lower the sharpness setting to eliminate 
them. 
Figure 4-5. Typical Test Pattern for Adjusting Sharpness
Input Position
Use the controls in the Input Position Menu to fine-tune the aspect ratio and image 
position for the current source.
Left/Right: Select Left/Right from the Input Position menu to shift the projected image 
horizontally. Use the right or up cursor button to shift the image to the right; use the left or 
down button to shift it to the left.
Up/Down: Select Up/Down from the Input Position menu to shift the projected image 
vertically. Use the right or up cursor button to shift the image upward; use the left or down 
button to shift it downward.
Width: Select Width from the Input Position menu to change the projected image width. 
Use the right or up cursor button to increase the width; use the left or down button to 
decrease it.
Height: Select Height from the Input Position menu to change the projected image 
height. Use the right or up cursor button to increase the height; use the left or down 
button to decrease it.
Input Position
Left/Right
Up/Down
Width
Height
Overscan
The input position settings are automatically saved for each input 
and resolution.
Note