Maretron gps200 Manuale Utente

Pagina di 23
 
GPS200 User’s Manual  
 
 
 
 
 
Page 10 
 
Revision 1.2
 
 
Electrical 
Parameter 
Value 
Comment 
Operating Voltage 
9 to 16 Volts 
DC Voltage 
Power Consumption 
<100mA 
Average Current Drain 
Load Equivalence Number (LEN) 
NMEA 2000
®
 Spec. (1LEN = 50 mA) 
Reverse Battery Protection 
Yes 
Indefinitely 
Load Dump Protection 
Yes 
Energy Rated per SAE J1113 
 
Mechanical 
Parameter 
Value 
Comment 
Size 
4” Diameter x 1.65” Tall  Not Including Antenna Mount Base 
Weight 
6 oz. 
Not Including Antenna Mount Base 
Mounting 
Deck or Pole 
 
 
Environmental 
Parameter 
Value 
IEC 60954 Classification 
Exposed 
Degree of Protection 
IP67 
Operating Temperature 
-25°C to 55°C 
Storage Temperature 
-40°C to 70°C 
Relative Humidity 
93%RH @40° per IEC60945-8.2 
Vibration 
2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7 
Rain and Spray 
12.5mm Nozzle @ 100liters/min from 3m for 30min per IEC 60945-8.8 
Solar Radiation 
Ultraviolet B, A, Visible, and Infrared per IEC 60945-8.10 
Corrosion (Salt Mist) 
4 times 7days @ 40°C, 95%RH after 2 hour Salt Spray Per IEC 60945-8.12 
Electromagnet Emission 
Conducted and Radiated Emission per IEC 60945-9 
Electromagnetic Immunity 
Conducted, Radiated, Supply, and ESD per IEC 60945-10 
Safety Precautions 
Dangerous Voltage, Electromagnetic Radio Frequency per IEC 60945-12 
 
 
7  Technical Support 
If you require technical support for Maretron products, you can reach us in one of the following 
ways: 
 
 Telephone: 
1-866-550-9100 
 Fax: 
1-602-861-1777 
 
World Wide Web: 
 Mail: 
Maretron, 
LLC 
 
  Attn: Technical Support 
 
  9014 N. 23
rd
 Ave Suite 10 
 
  Phoenix, AZ 85021 USA