Installations must be carried out by authorised 
persons only.  Failure to install equipment to 
the  relevant  codes  and  manufacturers  
specifications in this section will void warranty. 
This oven must be electrically grounded in  
accordance with local codes. 
 
 
BEFORE CONNECTION TO POWER  
SUPPLY
 
Unpack and check unit for damage and report 
any damage to the carrier and dealer.  Report 
any deficiencies to your dealer.  
 
Fitting legs
 
Tilt the oven over on one side and fit both the 
front and rear legs to the side now off the 
ground.  Fit them into the base frame under 
the chassis base and secure to the base with 
the bolts, spring washers and flat washers 
provided.  Lift up the other side of the oven, fit 
legs, bolts and washers, but do not tighten 
yet.  Position leg tray (flat side facing up)  
between legs and secure with the 4 screws 
provided, then tighten all leg bolts.  Level the 
oven by adjusting the feet. 
NOTE:  Double units have no leg tray.   
 
Stacking the ovens (Double units only) 
Lay the top unit on its side and fit the spacers 
provided to the base of the oven. 
Lift the top unit onto the bottom unit and  
secure around the spacer panel flanges with 
self-tapping screws provided.  Fit chimneys 
over the duct assembly of the bottom unit.  
Screw  in  place  and  pull  down  chimney  
surrounds onto the duct assembly.  Level the 
oven by adjusting the feet.  (Refer to appendix 
A for more detailed stacking instructions). 
 
 
LOCATION 
The  following  minimum  clearances  for  air 
openings, servicing, operation and installation 
are to be adhered to: 
2.  INSTALLATION 
WARNING:  THIS APPLIANCE MUST BE EARTHED / GROUNDED. 
Rear 
100mm / 4”  
Left-hand side 
100mm / 4” 
Right-hand side 
300mm / 12” 
NOTE:    300mm is required at the right hand 
side of the oven to allow access to the  
circuitry and gas connections.  If space is  
limited then a minimum of 100mm (4”)  
clearance should be allowed for, provided 
that  the  oven  can  be  moved  to  gain  
access.   
Position  the  oven  in  its  allocated  working  
position.  Use a spirit level to ensure the oven 
is level from side to side and front to back.  (If 
this is not carried out, uneven cooking could 
occur).  The feet/legs used with bench or floor 
mounting  or  provided  with  stands  are  
adjustable  and  will  require  adjusting  in  
levelling the unit.  It should be positioned so 
the operating panel and oven shelves are 
easily reachable for loading and unloading.   
 
 
ELECTRICAL CONNECTION 
This E1100 convection oven can be supplied 
as a single or twin deck unit.  Check that the 
available  power  supply  is  correct  to  that 
shown on the rating plate located on the right-
hand side panel. 
400-415V AC, 50Hz, 3P+N+E, L1 14.5A 
  
L2 
14.4A 
  
L3 
13.7A 
380V AC, 60Hz, 3P+N+E 
L1 15.9A 
  
L2 
15.8A 
  
L3 
15.0A 
The mains terminal block is positioned at the 
rear of the unit.  Access is provided by a  
detachable panel on the back panel.  Each 
oven should be connected to a circuit breaker 
(or  switch  and  fuses).   These  should  be 
mounted on the wall adjacent to the oven and 
should  be  readily  accessible  and  clearly 
marked. 
Bring the connecting cable up through the 
base panel and tighten the conductor strands 
securely to the terminal block studs.  The 
earth screw is located in the base panel next 
to the cable entry hole. 
WARNING:  ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED 
OUT BY QUALIFIED PERSONS ONLY.