4. During 
configuration, the motor and laser turn off.  YOU CANNOT SCAN A 
BAR CODE WHILE IN SERIAL CONFIGURATION MODE. 
 
5.  There is a 20 second window between commands.  If a 20 second timeout 
occurs, the scanner will send a [nak] and you must start over. 
 
6.  To enter serial configuration mode, send the following command 
[stx]999999[etx]. 
 
7.  To exit serial configuration mode, send the following command 
[stx]999999[etx], the scanner will respond with an [ack] followed by 3 beeps. 
 
8.  This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits 
settings that are configured in the scanner.  The default settings of the 
scanner are 9600, Space, 2, 7 respectively.  If a command is sent to the 
scanner to change any of these settings, the change will NOT take effect 
until after serial configuration mode is exited. 
 
EXAMPLE #2:  
 
The following example will set the scanner to the factory default settings, 
Disable Scanning of Code 128 bar codes, change the beeper tone, and add 
a “G” as a configurable prefix. 
 
 
FEATURE 
HOST 
COMMAND 
ASCII 
REPRESENTATION 
SCANNER  
RESPONSE 
Enter Configuration Mode
[stx]999999[etx]  02h 39h 39h 39h 39h 39h 39h 03h 
[ack] or 06h 
Load Defaults
 
[stx]999998[etx]  02h 39h 39h 39h 39h 39h 38h 03h 
[ack] or 06h 
Disable Code 128
 
[stx]100113[etx]  02h 31h 30h 30h 31h 31h 33h 03h 
[ack] or 06h 
Alternate Tone 1
 
[stx]318565[etx]  02h 33h 31h 38h 35h 36h 35h 03h 
[ack] or 06h 
Configure. Prefix #1
 
[stx]903500[etx]  02h 39h 30h 33h 35h 30h 30h 03h 
[ack] or 06h 
Code Byte 0
 
[stx]0[etx] 
02h 30h 03h 
[ack] or 06h 
Code Byte 7
 
[stx]7[etx] 
02h 37h 03h 
[ack] or 06h 
Code Byte 1
 
[stx]1[etx] 
02h 31h 03h 
[ack] or 06h 
Exit Configuration Mode 
[stx]999999[etx]  02h 39h 39h 39h 39h 39h 39h 03h 
[ack] or 06h 
The scanner will beep three times! 
 
The commands sent to the scanner do not include the small superscripted 
three ( 
3
 
) that you see in front of each bar code string in the MetroSelect 
manual.  THE THREE ( 
3
 ) SHOULD NOT BE SENT.  IT IS A CODE TYPE 
DESIGNATION ONLY! 
 
For commands requiring additional bar codes to be scanned (such as 
prefixes, suffixes, timeouts, etc.), simply send the code bytes in the same 
order that you would normally scan the bar codes.