National Instruments 653X Manuale Utente

Pagina di 147
© National Instruments Corporation
C-1
C
Connecting Signals with 
Accessories
This appendix describes how to connect signals to your 653device. Use 
the first part of the appendix to acquaint yourself with the device control 
signals. Then go to appropriate pinout diagrams (68 or 50-pin), which 
display the layout of pin locations.
Control Signals
Use the four control signals to regulate/control the timing of your data 
transfer when using the handshaking and pattern I/O modes. The direction 
and function of each signal varies, depending on the mode of operation, 
as shown in Table C-1.
Table C-1.  Control Signals for Handshaking I/O and Pattern I/O
Signal Name
 Handshaking I/O
 Pattern I/O
Direction
Function
Direction
Function
REQ<1..2>
Input
Request—Indicates 
that the peripheral 
device is ready
Input or 
Output
Request—
Clocks the data transfer
ACK<1..2>
or
STARTTRIG<1..2>
Output
Acknowledge—
Indicates the 653X 
device is ready
Input
Start trigger
STOPTRIG<1..2>
N/A
N/A
Input
Stop trigger
PCLK<1..2>
Input or 
Output
Peripheral clock
N/A
N/A