Zebra 49834 Manuale Utente
System Description
Media Specifications
57518L-001 Rev. A
3/18/05
170PAX4 Maintenance Manual
17
Media Specifications
Media width
(label and liner)
(label and liner)
Minimum
3.0 in. (76 mm)
Maximum
7.1 in. (180 mm)
Label length
Minimum
Applicator mode
3.0 in. (76.2 mm) with backfeed on
1.0 in. (25.4 mm) with backfeed off
Rewind mode
1.0 in. (25.4 mm)
Tear-off mode
3.0 in. (76.2 mm) with backfeed on
1.0 in. (25.4 mm) with backfeed off
Registration tolerance
(not including label/liner
position tolerances)
(not including label/liner
position tolerances)
Vertical
(concurrent labels)
(concurrent labels)
±0.040 in. (±1.0 mm)
(in Applicator mode)
(in Applicator mode)
Horizontal
±0.040 in. (±1.0 mm)
Total thickness (including liner)
0.003 in. to 0.012 in. (0.076 mm to 0.305 mm)
Interlabel Gap
(Transmissive Sensor)
(Transmissive Sensor)
Minimum
0.079 in. (2 mm)
Preferred
0.118 in. (3 mm)
Maximum
0.157 in. (4 mm)
Notch
Size (W x L)
0.25 in. x 0.12 in. (6 mm x 3 mm)
Position
On inside edge, <0.8 in (<20 mm) from leading
edge of media
edge of media
Hole
Minimum
0.125 in. (3.2 mm)
Position
0.25 to 3.0 in. (6.3 to 76.2 mm) from inside edge
<0.8 in. (<20 mm) from leading edge of media
Black Mark
(Reflective Sensor)
(Reflective Sensor)
Vertical length (parallel
to inside media edge)
to inside media edge)
0.12 in. to 0.43 in. (3 mm to 11 mm)
Horizontal width
(perpendicular to inside
media edge)
(perpendicular to inside
media edge)
0.43 in. (11 mm) minimum
Position
One of the following:
• within 0.04 in. (1 mm) of the inside edge and
<0.8 in (20 mm) from leading edge of media
• centered within 0.23 in. to 2.25 in. (5.8 to
57 mm) from the media inner edge
Density
> 1.0 Optical Density Units (ODU)
Maximum media density: 0.5 ODU
Print Line to Peel Bar Distance
0.464 in. (11.8 mm)
Media Unwind Force
Steady State
Must be uniform and must not exceed 2 lb. (907 g)
Transient (Start/Stop)
Must not exceed 4 lb (1814 g)
Media Rewind Force
Applicator take-up pull tension must be uniform
from 1 to 4 lb (454 to 1818 g) and must not vary
more than ±20% during operation.
from 1 to 4 lb (454 to 1818 g) and must not vary
more than ±20% during operation.