Controller LED will start blinking 
You will have four minutes to complete the next steps before linking mode times out
 
2)  Adjust load connected to Micro module to desired brightness level (even off) 
3)  Press and hold Micro module Set button until it double-beeps 
Controller will double-beep and its LED will stop blinking
 
4)  Test link by tapping controller button on and off 
Load connected to Micro module will respond appropriately 
 
Make Micro Module a Responder (Switch) 
1)  Press and hold controller Set button until it beeps 
Controller LED will start blinking 
You will have four minutes to complete the next steps before linking mode times out
 
2)  Adjust load connected to Micro module to desired level (on or off) 
3)  Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or 
dual momentary switch, alternate switch directions: up-down-up-down-up or down-up-down-up-down.) After 
tapping switch, wait two seconds. 
Micro module will double-beep 
Controller will double-beep and its LED will stop blinking
 
4)  Test link by tapping controller button on and off 
Load connected to Micro module will turn on and off
 
 
Make Micro Module a Controller (Set button) 
Note: you must perform these steps before reinstalling the wall switch, outlet or fixture. 
1)  Press and hold Micro module Set button until it beeps 
Micro module LED will start blinking green 
You will have four minutes to complete the next steps before linking mode times out
 
2)  Adjust responder to desired state
 
3)  Press and hold responder Set button until it double-beeps 
Micro module will double-beep and its LED will stop blinking
 
4)  Test link by tapping or pressing and holding Micro module on/off buttons to turn on/off or brighten/dim 
Responder will respond appropriately 
 
Make Micro Module a Controller (Switch) 
1)  Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or 
dual momentary switch, alternate switch directions: up-down-up-down-up or down-up-down-up-down.) After 
tapping switch, wait two seconds. 
Micro module will beep to indicate it has entered linking mode 
You will have four minutes to complete the next steps before linking mode times out
 
2)  Adjust responder to desired state
 
3)  Press and hold responder Set button until it double-beeps 
Micro module will double-beep and its LED will stop blinking 
4)  Test link by tapping switch connected to Micro module to turn on/off or brighten/dim 
Responder will respond appropriately
 
 
                                                      