Motor assembly
#79018 (790 series)
#79020 (792 series)
Mounting block
#79007
Mounting stud
#HM3X16MM
Note: Replacement 
motor housing complete 
with mounting studs 
#79021
11
Servicing the fluid body
4.  Remove the fluid inlet fitting and
clean thoroughly.
5.  Remove the fluid body retaining
nuts and lock washers. Remove
the fluid body by pulling it straight
off the auger. Clean thoroughly.
6.  Loosen auger set-screw and
remove auger and seal assembly.
Clean auger carefully and replace
the seal (#79011). Ensure that the
open end of the seal faces the
outlet end of the valve.
7.  Inspect the auger and fluid body
for damage or wear. If necessary,
replace the worn components.
8.  Reassemble in reverse order.
Servicing the drive-motor assembly
The drive motor, motor chamber, cable
and strain relief are supplied as an
assembly. In the event of a drive motor
failure, replacement of drive motor
assembly is recommended (valve model
790, #79018; valve model 792, #79020).
9.  Disconnect the power cable from
the controller.
10.  Remove the fluid body and auger.
11.  Attach the auger and fluid body to
the replacement drive motor
assembly.
12.  Connect the power cable to con-
nector pins 7 & 8.
Maintenance Tools: 
6" adjustable wrench 
1/8" hex wrench EFD #7316B
1.5 mm hex wrench EFD # 7900
2.5 mm hex wrench EFD # 7901