Eaton PC2641-D-FF Manuale Utente
© 2008 Eaton Corporation. All Rights Reserved. All specifications are subject to change without notice.
www.pulizzi.com • pulizzisales@eaton.com • 800-870-2248 • Fax: 605-334-4999
2
RACK MOUNTED
•
19” x 3.4” (2U) x 14.5” (recessed)
•
Approximate weight: 29 lbs.
(14) NEMA OUTLETS
•
2 unswitched outlets
•
12 switched outlets, 4 per phase
(4) INDICATOR LIGHTS
•
Main breaker power “on” to system and
unswitched duplex
•
Power “on” to PH-X, -Y, -Z outlets
SPIKE/SURGE SUPPRESSION
•
320V MOV L-N
EMI/RFI FILTERING
•
Common Mode - Line to Ground
•
Differential Mode - Line to Line
LOCAL/OFF/REMOTE SWITCHING
•
Local: Power “on or off” to the switched
outlets
•
Off: When breaker is “on” but this switch
is in the “off” mode, you will have power
to the unswitched outlets only
•
Remote: Power “on or off” to the
switched outlets via a remote device
•
When using the Latching remote, the
selection switch is wired for
Remote/Off/Remote. There is no local
Remote/Off/Remote. There is no local
control.
MULTIPLE TIME DELAY™ (MTD™)
•
PH-X powers up immediately, followed
4-seconds later by PH-Y, which is
followed 4-seconds later PH-Z, then
4-seconds later the sequenced remote
activates the next system in line
followed 4-seconds later PH-Z, then
4-seconds later the sequenced remote
activates the next system in line
•
PC2641-D/MTD and PC2641-D/LT
only models
only models
POWER INPUT
•
Power cable with plug is attached to unit
through the front panel cable grip
through the front panel cable grip
BRANCH CIRCUIT PROTECTION
•
UL498 Listed electromagnetic breakers,
with a long time delay curve, provide
both manual on/off switching and trips
automatically in an overload condition
4 REMOTE I/O PORTS
•
Remote on/off and EPO control,
EPO overrides remote and local control
EPO overrides remote and local control
•
Sequence Power Up additional
equipment down line (standard on all units)
equipment down line (standard on all units)
•
Latching remote - normally closed EPO,
momentary start. Units with “LT” in
part number, i.e. PC2641-D-LT or /LT
momentary start. Units with “LT” in
part number, i.e. PC2641-D-LT or /LT
SPECIFICATIONS
PC2641-D
PC2641-D-LT
PC2641-D/MTD
PC2641-D/LT
Voltage Input Three Phase (50/60Hz)
120/208V~
120/208V~
120/208V~
120/208V~
Voltage Output Single Phase (50/60Hz)
120V~
120V~
120V~
120V~
Current Input Per Phase
30A
Per Phase
30A
Per Phase
30A
Per Phase
30A
Per Phase
Current Output Per Phase
24A
Per Phase
24A
Per Phase
24A
Per Phase
24A
Per Phase
Full Load VA Per Phase
2880VA
Per Phase
2880VA
Per Phase
2880VA
Per Phase
2880VA
Per Phase
NEMA Outlets
5-20R
5-20R
5-20R
5-20R
Main Circuit Breaker (on/off switch)
30/30/30A
30/30/30A
30/30/30A
30/30/30A
Secondary Circuit Breakers Per Phase
20/20A
20/20A
20/20A
20/20A
Unswitched Duplex Circuit Breaker
20A
20A
20A
20A
EMI/RFI Filter
30A
30A
30A
30A
Surge Suppression
320V
320V
320V
320V
Power Cord/Length/Plug
10/5, 15’, L21-30P
10/5, 15’, L21-30P
10/5, 15’, L21-30P
10/5, 15’, L21-30P
Remote Control
Standard Remote
Latching Remote
Standard Remote
Latching Remote
Multiple Time Delay
NO
NO
YES
YES
PC2641-D Rear
Front