Command:
AT+CLM
Expected Response:
XXXXXXXXXXXXXX
Power Commands
View Stationary Transmit Interval
View the current transmit interval used while the device is stationary or while motion sensor
is turned off.
Command:
AT+PARAM=”STATTRANS”
Expected Response:
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: STATTRANS=<stat>
OK
OK
<stat>: Transmit interval in seconds
Set Stationary Transmit Interval
Set a new transmit interval used while the device is stationary or while motion sensor is
turned off.
Command:
AT+PARAM=”STATTRANS”,”<stat>”
<stat>: Transmit interval in seconds
Expected Response:
OK
View Powered Transmit Interval
View the current transmit interval used while external power is applied to the device.
Command:
AT+PARAM=”POWTRANS”
Expected Response:
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: POWTRANS=<pow>
+SYSSTAT: POWTRANS=<pow>
OK
<pow>: Transmit interval in seconds
Prepared: R. Straz
Date: July 25, 2007
Page 69 of
139