System Planning Corporation GTLITEV3 Manuale Utente
GlobalTrak ™
GT Lite Operation and Maintenance Manual
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: OPTIC=<optic>
+SYSSTAT: OPTIC=<optic>
OK
<optic>:
Optic threshold in digital steps. 0 – 1023
Set Optic Threshold
Set a new threshold set for optic events.
Command:
AT+PARAM=”OPTIC”,”<optic>”
<optic>:
Optic threshold in digital steps. 0 – 1023
Expected Response:
OK
View Shock Threshold
View the threshold set for shock events.
Command:
AT+PARAM=”SHOCK”
Expected Response:
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: SHOCK=<shock>
+SYSSTAT: SHOCK=<shock>
OK
<shock>: Shock
threshold
in milli g’s. 0 – 18000
Set Shock Threshold
Set a new threshold set for shock events.
Command:
AT+PARAM=”SHOCK”,”<shock>”
<shock>: Shock
threshold
in milli g’s. 0 – 18000
Expected Response:
OK
View Low Temperature Threshold
View the threshold set for low temperature events.
Command:
Prepared: R. Straz
Date: July 25, 2007
Page 81 of