System Planning Corporation GTLITEV3 Manuale Utente

Pagina di 139
GlobalTrak ™ 
GT Lite Operation and Maintenance Manual 
 
AT+PARAM=”TEMPLOW” 
Expected Response: 
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter. 
+SYSSTAT: TEMPLOW=<templow> 
OK 
 
<templow>: Low 
temperature threshold 
   
 
˚C = <templow>*0.1693 - 50 
 
Set Low Temperature Threshold 
Set a new threshold set for low temperature events. 
Command: 
AT+PARAM=”TEMPLOW”,”<templow>” 
<templow>: Low 
temperature threshold 
 
  <templow> 
(˚C – 50)/0.1693 
 
Expected Response: 
OK 
 
View High Temperature Threshold 
View the threshold set for high temperature events. 
Command: 
AT+PARAM=”TEMPHIGH” 
Expected Response: 
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter. 
+SYSSTAT: TEMPHIGH=<temphigh> 
OK 
 
<temphigh>: High 
temperature threshold 
   
 
˚C = <temphigh>*0.1693 - 50 
 
Set High Temperature Threshold 
Set a new threshold set for high temperature events. 
Command: 
AT+PARAM=”TEMPHIGH”,”<temphigh>” 
<temphigh>: High 
temperature threshold 
 
  <temphigh> 
(˚C – 50)/0.1693 
 
Expected Response: 
OK 
  Prepared:  R. Straz 
Date: July 25, 2007 
 
Page 82 of 
139