AT+PARAM=”TEMPLOW”
Expected Response:
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: TEMPLOW=<templow>
+SYSSTAT: TEMPLOW=<templow>
OK
<templow>: Low
temperature threshold
˚C = <templow>*0.1693 - 50
Set Low Temperature Threshold
Set a new threshold set for low temperature events.
Command:
AT+PARAM=”TEMPLOW”,”<templow>”
<templow>: Low
temperature threshold
<templow>
=
(˚C – 50)/0.1693
Expected Response:
OK
View High Temperature Threshold
View the threshold set for high temperature events.
Command:
AT+PARAM=”TEMPHIGH”
Expected Response:
APPLICATION: (SYSSTAT_ParamCommandHandler) Enter.
+SYSSTAT: TEMPHIGH=<temphigh>
+SYSSTAT: TEMPHIGH=<temphigh>
OK
<temphigh>: High
temperature threshold
˚C = <temphigh>*0.1693 - 50
Set High Temperature Threshold
Set a new threshold set for high temperature events.
Command:
AT+PARAM=”TEMPHIGH”,”<temphigh>”
<temphigh>: High
temperature threshold
<temphigh>
=
(˚C – 50)/0.1693
Expected Response:
OK
Prepared: R. Straz
Date: July 25, 2007
Page 82 of