4.3  Digital pad ratings 
Symbol 
Parameter 
Conditions 
Min. 
Max. 
Units 
V
IH
 
Input high voltage 
 
0.7*VIO
5
 
VIO
1
 
V
IL
 
Input low voltage 
 
-0.3 
0.6
6
 
V
HYS
 
Input hysteresis 
 
0.18 
V
OH
 
Output high voltage 
I
O
max = 5 mA 
VIO-0.4 
V
OH
 
Output low voltage 
I
O
max
 
= -5 mA 
0.4 
Table 6: Digital pad ratings 
4.4  Peak current consumption 
Operation Mode 
Peak current typ. (mA) 
3V3 
VIO 
5V0_A1, 5V0_A2 
Idle 
 
372 
0.55 
1.7 
RX single antenna 
 
382 
0.45 
30 
RX dual antenna 
(5V0 peak current applies to each RX 
chain) 
 
461 
0.55 
30 
TX single antenna 
 
+0 dBm 
432 
0.45 
186 
+10 dBm 
434 
0.45 
197 
+20 dBm 
437 
0.45 
273 
TX dual antenna 
(output power and 5V0 peak current 
apply to each TX chain) 
+0 dBm 
563 
0.55 
186 
+10 dBm 
565 
0.55 
197 
+20 dBm 
570 
0.55 
273 
Table 7: Peak current consumption (typical values are referenced to T
A
 = +25 °C, 3V3 = 3.3 V, VIO = 1.8 V, 5V0_A1 = 5V0_A2 
= 5.0 V) 
☞ 
The average current consumption for full operation mode strongly depends on the RX/TX time 
ratio and remains within the range between the peak values of RX and TX. 
                                                                 
5
 1PPS pad always use 1.8 V internally generated IO supply regardless of the VIO pad voltage. 
6
 RSTn pad internally pulled high to VIO voltage by 100k. During reset it should be below 0.2 V.