u-blox AG VERAP174 Manuale Utente

Pagina di 30
VERA-P1 series - Data Sheet 
UBX-17004377 - R06_draft
 
Confidential 
Electrical specification 
 
 
Page 14 of 30 
4  Electrical specification 
⚠ 
Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating 
section may cause permanent damage. These are stress ratings only. Operating the module at 
these or at any conditions other than those specified in the Operating conditions section of this 
document  should  be  avoided.  Exposure  to  absolute  maximum  rating  conditions  for  extended 
periods may affect device reliability. 
☞ 
Operating  condition  ranges  define  those  limits  within  which  the  functionality  of  the  device  is 
guaranteed. Where application information is given, it is advisory only and does not form part of 
the specification. 
4.1  Absolute maximum ratings 
Symbol 
Description 
Min.  
Max. 
Units 
5V0_A1, 
5V0_A2 
Power supply voltage 5.0 V 
-0.3 
6.0 
3V3 
Power supply voltage 3.3 V 
-0.3 
3.9 
VIO 
I/O supply voltage 1.8 V/2.5 V/3.3 V 
-0.3 
3.9 
T
STORAGE
 
Storage temperature 
-40 
+95 
ºC 
Table 4: Absolute maximum ratings 
⚠ 
The  product  is  not  protected  against  overvoltage  or  reversed  voltages.  If  necessary,  voltage 
spikes exceeding the power supply voltage specification, given in table above, must be limited to 
values within the specified boundaries by using appropriate protection devices. 
4.2  Operating conditions 
Symbol 
Parameter 
Min.  
Typ 
Max. 
Units 
5V0_A1, 
5V0_A2 
Power supply voltage 5.0 V 
4.5 
5.0 
5.5 
3V3 
Power supply voltage 3.3 V 
3.0 
3.3 
3.6 
VIO 
I/O supply voltage 1.8 V/2.5 V/3.3 V 
1.65 
1.8 
1.95  
2.3 
2.5 
2.8 
 
3.0 
3.3 
3.6 
T
A
 
Ambient operating temperature 
-40 
+95 
ºC 
Ripple Noise  Peak-to-peak voltage ripple on 5V0 and 3V3 
supply lines. 
10 
mV 
Table 5: Operating conditions
4
 
                                                                 
4
 Min and Max limits apply for T
A
 = +25 °C.