Operation 
 
18  
 
EverGuard Express 
 
4.  Using the number keys, enter the number of the user to be deleted. One 
good beep is sounded. 
5.  Using the number keys, enter the PIN code 0000. Three beeps confirm that 
the user is deleted. Programming mode automatically ends and the status 
LED turns off. 
 
 
Note: If the deleted user has an associated key fob or tag, the key fob and 
tag stops working. 
 
3.7 
Defining Peripherals
 
 
The EverGuard Express control panel can support up to:
 
 
 
10 (32*) Detectors 
 
8 RF Input Devices 
 
8 RF Output Devices 
 
8 Key fobs 
 
8 Tags 
 
2 Keypads 
 
2 Display Voice Keypad  
 
3 Tag Readers 
 
4 Internal/External Sirens 
 * In case of DVK learnt on the control panel 
Defining peripherals can be done only with the AM application. 
3.8 
Setting Exit/Entry Times 
The entry/exit time is the time period between entry/exit and activation of the 
alarm. This time period can be lengthened or shortened. 
 
To set the Entry time: 
1.  Insert the Programming tool point into the Programming button. The Status 
LED flashes red and one good beep sounds. 
2.  Using the number keys, enter the master PIN code. The Status LED flashes 
green and one good beep is sounded. Programming mode is initiated. 
3.  Using the number keys, press 06. The Status LED flashes green and one good 
beep is sounded. 
4.  Using the number keys, enter the Entry time (seconds) in two digits. One 
good beep is sounded. Programming mode automatically ends and the status 
LED turns off. 
 
To set the Exit time: 
1.  Insert the Programming tool point into the Programming button. The Status 
LED flashes red and one good beep sounds.