Essence Security International ltd. ES7000EG Manuale Utente

Pagina di 71
 
Installation 
 
 
6  
 
EverGuard Control Panel 
 
2  Installation  
2.1  ES7000EG Wall Mount 
The ES7000EG can be mounted on a wall using the wall mount provided. In 
addition, you must verify that there is adequate reception from the key pad 
(ES700KPD) to the ES7000EG control panel and vice versa. 
 
 
Note: The distance between the ES7000EG control panel and the 
peripheral devices can be a maximum of 700 meters (2296 feet) (Open Air 
Nominal) if there are no obstacles. The range can be augmented using the 
ES700SOIR Repeater. (For more information on the ES700SIOR, refer to 
the ES700SIOR User Guide.) 
 
Mounting the ES700KPD requires the following components: 
 
Drill with appropriate bit 
 
Four (4) DIN 7982 cross recessed countersunk head tapping screws (4.2 x 40 
mm) (not provided) 
 
Standard appropriate screwdriver 
 
To select a mounting location: 
1.  Find a suitable wall location: 
  Select a suitable location that is not too obvious, a secret or hidden 
location that is not close to entry points, such as doors and windows. 
  The control panel must be located in an area that has good GSM signal 
reception.  
  The control panel must be installed with a minimal distance of 20 cm 
(0.66 ft) from users and nearby persons and must not be co-located or 
operating in conjunction with any other antenna or transmitter. 
  The minimal installation height from the floor must be 70 cm (2.3 ft), and 
at least 50 cm (1.65 ft) below the ceiling. 
  The control panel should be installed in a centric location, which means 
centered between all the rooms and all the floors in the building. 
  The control panel should not be installed near: 
 
 High current electric appliances such refrigerators, washing 
machines, electric or fuse boxes, etc.  
 
Appliances such as cordless phones, TVs, which could cause 
interference.  
 
Heat sources such as stoves, radiators, or fireplaces, etc. 
 
In any kind of metal enclosures like a metal cabinets or lockers. 
2.  Only after all the RF devices have been installed and tested, should the 
installer mount the panel.