Section 4 : Electrical Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
37 
June 2015 
 
 
The controller supports neither LED1 nor LED2 signals 
When  the  access  controller  has  no  relay  contact  to  provide  an  answer  to  the 
MorphoAccess® terminal, then the decision to emit either the “access granted” signal 
or the “access denied” signal is taken by another way. It is either the MorphoAccess® 
terminal  itself  that  decide,  or  it  waits  for  the  access  controller  answer  through  the 
local area network (TCP), or on the RS-485 serial port. 
It is strongly recommended to disable the LED IN feature, to avoid any interference 
on MorphoAccess terminal behavior. 
The controller supports only LED1 signal 
When  the  access  controller  has  only  one  relay  contact  which  is  dedicated  to  the 
“access  granted”  answer,  this  one  must  be  connected  between  the  LED1  and  GND 
wires. The LED1 wire is set to the low level by closing the contact between the LED1 
and the GND wires, and it means “access granted”. 
The MorphoAccess® terminal uses the timeout of the wait for a low level on the on 
LED1 wire or LED2 wire as “access denied” answer. 
To  minimize  at  most  the  waiting  time  of  the  user,  the  MorphoAccess®  SIGMA  Lite 
Series terminal timeout value, must be adjusted to a value a little bit higher than the 
maximal value of the controller response time. 
Warning: if the LED2 wire is connected, it must be constantly maintained in the high 
state. 
The controller supports LED1 and LED2 signals 
When  the  controller  supports  one  relay  contact  for  each  of  the  possible  answers 
then: 
 
The « access granted » contact must be connected between the LED1 and the GND 
wires of the terminal 
 
The « access denied » contact must be connected between the LED2 and the GND 
wires of the terminal.  
The MorphoAccess® terminal considers that: 
 
The  answer  of  the  controller  is  "access  granted",  when  the  controller  puts  the 
LED1 wire to the low state (by closing a contact between the LED1 and the GND 
wires), and leaves the LED2 wire to the high state. 
 
The answer of the controller is "access denied", when the controller puts the LED2 
wire to the low state (by closing a contact between the LED2 and the GND wires), 
whatever is the state of the LED1 wire. 
The  MorphoAccess®  terminal  also  considers  that  the  answer  of  the  controller  is 
"access denied" in case of time-out while expecting for a closure between LED1 and 
GND wires, or between LED2 and GND wires.