Section 4 : Electrical Interface
2015_2000007248-V1 - Draft
This document and the information therein are the property of Morpho. They must not be
copied or communicated to a third party without the prior written authorization of Morpho
39
June 2015
Data Clock Output
The following figure shows how to cable the wires of the Wiegand OUT port of the
terminal for Data Clock protocol. This is used, for instance, to connect the
MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP).
terminal for Data Clock protocol. This is used, for instance, to connect the
MorphoAccess® SIGMA Lite terminal to an Access Control Panel (ACP).
Figure 17: Wiegand port wiring – Data Clock
17 Blue
WIEGAND_LEDOUT1 Out
Data ( 5V TTL )
18 Blue / Red
WIEGAND_LEDOUT2 Out
Clock ( 5V TTL )
20 Black / Red
WIEGAND_GND
Ground for Wiegand