IDEMIA Identity & Security France MPHAC001A Manuale Utente

Pagina di 74
 
Section 5 : User Interface 
 
 
2015_2000007248-V1 - Draft 
This document and the information therein are the property of Morpho. They must not be 
copied or communicated to a third party without the prior written authorization of Morpho 
52 
June 2015 
 
 
Anti-tamper / anti-pulling switches 
Please refer also to “Tamper Switch” section. 
These  switches  are  activated  as  soon  as  there  is  enough  pressure  applied  on  the 
terminal  against  the  wall.  They  are  deactivated  as  soon  as  this  pressure  is  not  big 
enough, e.g. when the terminal is pulled out of the wall. 
When the  switches  are deactivated, the  MorphoAccess®  SIGMA  Lite  Series  terminal 
acts  as  required  by  the  related  configuration  key  (see  MorphoAccess®  SIGMA  Lite 
Series Administrator / User Guide for key configuration description): 
 
Ignore the event (default): useful during normal maintenance operations. 
 
Send an alarm message to the Central Access Controller, through the usual channel 
of  the  access  control  result  messages  (Wiegand,  DataClock,  RS485,  Ethernet  or 
Wi-Fi™).  An  alarm  switch  (relay  contact)  is  directly  available  on  block  terminal 
«tamper switch pins». Please refer to “Wiring overview” and to “Tamper Switch” 
sections. 
 
Generate  an  audible  alarm  signal  with  the  speaker  and  an  alert  message  on  the 
screen.