Configuring the terminal 
MorphoAccess® SIGMA Lite Series terminals are standalone biometric systems which 
offers  advance  features  for  access  control.  MorphoAccess®  SIGMA  Lite  Series 
terminals  are  equipped  with  a  facility  to  support  the  MorphoAccess®  and  Bioscrypt 
legacy systems. 
When MorphoAccess® SIGMA Lite Series terminal is set in any of the legacy modes, it 
supports  the  database  structures  and  configurations  of  the  selected  legacy  system. 
When the  terminal  is booted  for  the  first  time, user  can  select  any of the  following 
modes: 
MorphoAccess® 500 or J Series legacy mode 
MorphoAccess®  SIGMA  Lite  Series  terminal  can  be  operated  in  MorphoAccess
®
  500 
or  J  series  mode  (also  referred  as  Legacy  Morpho).  In  this  mode,  the  terminal  will 
support  configurations  and  operations  of  MorphoAccess
® 
500  series  terminals. 
Terminal can authenticate users enrolled in the  MorphoAccess
® 
500 series terminal, 
using biometric check as well as contactless card. New users can also be enrolled in 
MorphoAccess
® 
500 series mode. 
 
Once the product is configured in Legacy Morpho mode, the following methods can 
be used to configure the terminal: 
 
through the Ethernet interface (remote management) 
 
through a Wi-Fi™ connection (license and dongle required) 
Configuration procedures are described inside the MorphoAccess® SIGMA Lite Series 
Administration Guide as follows: 
 
Section 4: Terminal Configuration And Administration 
Bioscrypt 4G Series legacy mode 
MorphoAccess®  SIGMA  Lite  Series  can  be  operated  in  Bioscrypt  4G  mode  (also 
referred as Legacy L1). In this mode, the terminal will support limited operations and 
configurations that are done using Secure Admin application. The terminal in L1 mode 
is  able  to  authenticate  the  users  enrolled  on  4G  terminals  and  contactless  cards. 
However it is not possible to enrol users in legacy L1 mode on MorphoAccess® SIGMA 
Lite Series terminal. 
In  case,  users  are  enrolled  in  MA5G  mode,  the user  data  cannot be  exported  when 
terminal is in L1 mode. 
Once  the  product  is  configured  in  Legacy  L1  mode,  the  following  methods  can  be 
used to configure the terminal: 
 
through the Ethernet interface (remote management) 
 