DIXELL S.r.l. 01XRCHC Manuale Utente

Pagina di 7
 
XRB60CHC EN r1.1 2018.11.01.docx 
                           XRB60CHC 
1/7 
 
DIGITAL CONTROLLER WITH ADVANCED 
ENERGY SAVING MANAGEMENT AND 
BLUETOOTH CONNECTIVITY 
XRB60CHC 
1
 
GENERAL WARNINGS ................................................................................................................................... 1
 
2
 
GENERAL DESCRIPTION .............................................................................................................................. 1
 
3
 
REGULATION .................................................................................................................................................. 1
 
4
 
ENERGY REDUCTION ALGORITHM ............................................................................................................ 1
 
5
 
EXTRA COOLING FUNCTION ....................................................................................................................... 2
 
6
 
EVAPORATOR FANS ..................................................................................................................................... 2
 
7
 
DEFROST ........................................................................................................................................................ 2
 
8
 
INTERNAL COUNTERS .................................................................................................................................. 2
 
9
 
FRONT PANEL COMMANDS ......................................................................................................................... 3
 
10
 
PARAMETERS ................................................................................................................................................ 3
 
11
 
DIGITAL INPUT ............................................................................................................................................... 5
 
12
 
INSTALLATION AND MOUNTING.................................................................................................................. 5
 
13
 
OPTIONAL FEATURES .................................................................................................................................. 5
 
14
 
ELECTRICAL CONNECTIONS ....................................................................................................................... 5
 
15
 
USE THE HOT KEY......................................................................................................................................... 6
 
16
 
ALARM SIGNALLING ...................................................................................................................................... 6
 
17
 
TECHNICAL DATA .......................................................................................................................................... 6
 
18
 
WIRINGS .......................................................................................................................................................... 6
 
19
 
APPLICATION NOTES .................................................................................................................................... 6
 
20
 
BLUETOOTH COMMUNICATION .................................................................................................................. 6
 
 
GENERAL WARNINGS 
1.1 
PLEASE READ BEFORE USING THIS MANUAL 
• 
This  manual  is  part  of  the  product  and  should  be  kept  near  the  instrument  for  easy  and  quick 
reference. 
• 
The instrument shall not be used for purposes different from those described hereunder. It cannot be 
used as a safety device. 
• 
Check the application limits before proceeding. 
• 
Dixell Srl reserves the right to change the composition of its products, even without notice, ensuring 
the same and unchanged functionality. 
1.2 
SAFETY PRECAUTIONS 
• 
Check the supply voltage is correct before connecting the instrument. 
• 
Do not expose to water or moisture: use the controller only within the operating limits avoiding sudden 
temperature changes with high atmospheric humidity to prevent  formation of condensation 
• 
Warning: disconnect all electrical connections before any kind of maintenance. 
• 
Fit the probe where it is not accessible by the End User. The instrument must not be opened. 
• 
In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” (see 
address) with a detailed description of the fault. 
• 
Consider the maximum current which can be applied to each relay (see Technical Data). 
• 
Ensure that the wires for probes, loads and the power supply are separated and far enough from each 
other, without crossing or intertwining. 
• 
In case  of applications in industrial environments, the use of  mains filters  (our mod. FT1) in parallel 
with inductive loads could be useful. 
GENERAL DESCRIPTION 
The XRB60CHC32x74x60mm format, is a microprocessor based controller suitable for applications 
on  medium  or  low  temperature  ventilated  refrigeration  units.  It  has  3  relay  outputs  to  control 
compressor, fans, light and defrost or auxiliary output. The device is also provided with up to 4 NTC 
probe inputs: the first one for temperature control, the second one to be located onto the evaporator to 
control the defrost termination temperature and to manage the fan and the third, optional and located 
on the HOT-KEY port, used to control the condenser temperature. There is also a configurable digital 
input. By using the HOT-KEY it is possible to program the instrument in a quick and easy way. 
The controller has Bluetooth 4.2 connectivity.  
REGULATION 
The  regulation  is  performed  according  to 
the  temperature  measured  by  the 
thermostat  probe  with  a  positive 
differential  from  the  set  point:  if  the 
temperature  increases  and  reaches  set 
point  plus  differential,  the  compressor  will 
start.  The  compressor  will  stop  when  the 
temperature  reaches  the  set  point  value 
again. 
 
In  case  of  fault  because  of  the  thermostat  probe,  the  start  and  stop  of  the  compressor  are  timed 
through parameters CoF and Con
ENERGY REDUCTION ALGORITHM 
4.1 
DESCRIPTION 
The device permits to set different temperature to be used during normal and reduced power use. The 
standard SET-POINT (SET) is used to maintain the temperature  at a certain  value when the  energy 
saving status (ES) is not active. On the other side, when the ES status is active a different SET-POINT 
(SET_ES),  higher  than  the  standard  one,  will  be  used.  The  parameter  HES  will  have  to  be  set  to 
change the regulation temperature according to the following formula: 
SET_ES = SET + HES 
There are also two different differential  values for  SET and SET_ES, which are used for compressor 
cut-in  and  cut-out:  when  ES  status  is  active  the  HYE  parameter  will  be  used  instead  of  the  HY 
parameter. 
 
The  device  uses  special  Energy  reduction  Algorithm  (ErA  algorithm  from  Dixell)  to  optimize  loads 
activation during the day. It is possible to set two different algorithms (ErA=bAS or Aut). They differ for 
the used sensor and for the total length of the interval of time involved. 
4.2 
BASIC ENERGY SAVING ALGORITHM – ErA=bAS 
This  will  be  used  when  ErA=bAS.  The  energy  saving  status  will  be  always  saved  in  the  internal 
memory to resume previous operation if a power failure occurs. It needs the presence of a door switch 
to work (i1F=dor). 
4.2.1 Parameter involved and suggested values: 
ErA=bAS 
i1F=dor 
StE=4.0 hours 
EtS=6.0 hours 
HES=4.0 to 5.0 °C 
HYE=3 to 4°C 
dS=5 to 10 sec 
LdE=Y 
 
FROM 
TO 
CHANGED BY 
Normal 
mode 
Energy 
Saving 
- Push the DOWN button for 3 sec (if enabled). 
- Door continuously closed for the StE time. 
Energy 
Saving 
Normal 
mode 
- Push the DOWN button for 3 sec (if enabled).  
- Controller in ES mode for the EtS time. 
- If the controller is in ES mode, it returns in Standard mode 
(normal set-point) after opening the door more than dS time. 
  
NOTE:  the  cycling  mode  (ES  -  Normal  mode  -  ES  -  etc.)  works  if  i1F=dor  and  EtS  and  StE  are 
different from zero. If EtS=0 or StE=0, the controller will not change the operating mode,
 
and it will be 
possible to change from the normal mode to the energy saving mode by using ES button or by setting 
i1F=ES. See the below diagrams where the status changing is depicted: 
 
 
 
4.3 
AUTOMATIC ENERGY SAVING ALGORITHM 
This  will  be  used  when  ErA=Aut.  The  operations  are  controlled  by  using  the  Aid  parameter.  After 
powering on the device, it automatically starts to analyze the temperature behavior by using the only 
room  temperature  probe.  In  this  way  it  can  build  the  best  energy  saving  model  according  to  the 
application. The device uses temperature behavior information of the previous Aid interval to manage 
the loads during the current period. When Aid is set to use long periods (Aid>1), a day-by-day model 
will be used during the first interval of time.  
4.3.1 Parameter involved and suggested values: 
ErA=Aut 
HES= 3.0 to 5.0°C 
LdE=Y 
Aid=1 or 7 
nCE=4 
nCC=8 
Pdt=2 
HYE=3 to 4°C 
PPU=P1 
tun=depends on the regulation probe placement 
 
NOTES: 
1. 
In case of any blackout, the calculated energy saving model will be reset. 
2. 
ErA can exclusively drive the light output by using the LdE parameter. When LdE=YES, the 
light output status will change according to the energy saving (ES) status: 
a. 
OFF if ES is active 
b. 
ON if ES is not active 
3. 
It is always possible to override the light output status by using the frontal button. Anyway, this 
modification will have a temporary impact on the lights if LdE=YES. In fact, ErA will take the 
control after the next ES status change. 
4. 
ErA does not need any door switch input to work.  
5. 
Be sure to place the room temperature probe in near the upper zone of the cabinet: this gives 
the best results in terms of temperature variation analysis. 
6. 
The Aid parameter indicates the interval of analysis as “number of days”. The suggested 
values for it are 1 or 7, depending on the particular application.