ZTE Corporation ZM8300G Manuale Utente

Pagina di 53
                                                         
ZTE ZM8300G Module Hardware User Manual
 
<All rights reserved. No distribution without prior permission of ZTE.>                                                               
49 
ohms  if  being  measured  from  the  metal  shell  of  the  device).  The  ground  resistance  of  a 
soldering iron tip should be less than 20 ohms. 
  A  factory  building  should  be  equipped  with  antistatic  ground  cables,  and  antistatic 
common ground points should be set up on each floor. The ground resistance of a factory 
building  should  be  less  than  1  ohm.  The  resistance  between  a  ground  cable  shared  by 
devices and an antistatic common ground point should be less than 1 ohm. 
  In  an  electrostatic  discharge  protected  area  (EPA),  antistatic  dual-circuit  wrist  straps 
should be available, all wrist straps should be inserted into dedicated wrist strap jacks, and 
tools,  devices,  and  ground  cables  that  are  fixed,  except  antistatic  wrist  straps  and mobile 
device tools, must not be grounded using alligator clips. 
  Ensure  that  tools'  and  devices'  antistatic  ground  points  are  connected  to  antistatic 
ground  cables  in  parallel.  Antistatic  common  ground  bars  are  preferred,  and  series 
connections are prohibited. 
  Ensure  that  SMT  devices,  board-assembled  devices,  devices  used  to  assemble  and 
commission  modules  and  systems,  and  devices/tools  with  antistatic  ground  points  (for 
example,  a  soldering  iron)  are  grounded  using  separate  antistatic  ground  cables.  That  is, 
separate  ground  cables  are  connected  from  metal  ground  parts  of  the  devices/tools  to 
antistatic ground cables, to ensure that the devices/tools are reliably grounded. 
  Set up EPAs according to ANSI/ESD S20.20 and IEC 61340-5-1 (international standard 
systems for ESD protection), and ensure that the electrostatic sensitivity (HBM) is less than 
100 V. That is, devices with the electrostatic sensitivity equal to or greater than 100 V can be 
effectively protected in EPAs. 
  Take antistatic measures for static-electricity-generating articles that are required in an 
EPA (for example, plastic parts, devices, and monitors used in the assembly procedure), for 
example, using an ionizing air blower, applying antistatic liquid, and using a static shielding 
bag/net. Ensure that electrostatic sensitive devices, boards, and components are 30 cm or 
more away from non-eliminable static-electricity-generating sources. Within the range 30 cm 
away from electrostatic sensitive devices, boards, and components, ensure that the friction 
voltage is less than 100 V. 
  Use  tools  made  of  antistatic  materials  to  turn  over  electrostatic  sensitive  devices, 
boards,  and  components,  for  example,  antistatic  foam,  antistatic  boxes,  antistatic 
vacuum-formed  plastic  boxes,  antistatic  tote  carts,  and  antistatic  shielding  bags.  Do  not 
place electrostatic sensitive devices, boards, and components directly in containers without 
ESD  protection,  for  example,  ordinary  EPE  trays,  ordinary  vacuum-formed  plastic  boxes, 
ordinary plastic bags, ordinary plastic boxes, ordinary hollow boxes, and tote carts without 
ESD protection. 
  Before transporting electrostatic sensitive devices, boards, and components in non-EPA 
areas,  for  example,  trans-plant  transportation,  perform  antistatic  closed  packaging  for  the