G FORCE PLUS RF Vehicle Monitor Installation Instructions 
 
 
June/07
 8 
 
 
Purple wires/secondary alarm: 
Use these wires to create a secondary alarm if desired.  
The contact on the purple wires is fused at 3 amps – do 
not create a circuit that exceeds this rating.  For 
customized help with your particular installation, contact 
Technical Assistance at BMI Technologies Inc. at 1-800-
563-8867.  Tie these wires back if they are not used. 
8.  Reconnect the battery and turn on the vehicle ignition to test the installation. 
‰ 
The vehicle should power up and the Vehicle will be in Maintenance Lockout.  The Vehicle 
Interface will display “MAINT LOCK OUT DD/MM/YYYY HH:MM”. 
‰ 
If the blue wires were connected for lift interrupt, the lift will be disabled. 
‰ 
If the purple wires were connected for a secondary alarm, the vehicle’s behavior will reflect a 
secondary alarm condition.  
 
 
 
 
 
 
9.  Complete or pause the installation. 
‰ 
Refer to the section in the Instruction Manual that explains how to program the Vehicle Monitor 
settings, OR 
‰ 
Disconnect the Vehicle Monitor and Wiring Harness and reconnect the Installation Bypass Plug 
to the end of the Wiring Harness to allow full vehicle use and to defer the programming of 
Vehicle Monitor settings. 
 
NOTE! 
If the installation test fails, contact Technical Assistance  
at BMI Technologies Inc. at 1-800-563-8867.